Objectives And Background: Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV). The CDP is a nondimensional ratio, derived from fundamental fluid dynamic principles. We sought to evaluate the correlation of CDP with FFR, CFR, and hyperemic stenosis resistance (HSR: ratio of pressure drop to APV) in human subjects.
Methods: Twenty-seven patients with reversible perfusion defects based on SPECT were consented for the study before cardiac catheterization. Distal coronary pressure and APV were measured simultaneously for each coronary lesion using a Combowire(©) during cardiac catheterization. Reference diameter, minimal lumen diameter, and %AS were obtained by quantitative coronary angiography. Maximum hyperemia was induced by IV adenosine (140 µg/kg/min). CDP was calculated as, (Δp)/(0.5 × ρ × APV(2) ). The density of blood (ρ) was assumed to be 1.05 gm/cm(3) .
Results: The functional index, CDP, when correlated simultaneously with FFR and CFR, was found to have a significant correlation (r = 0.61; P < 0.05). Similarly a significant correlation was achieved when CDP was correlated with HSR (r = 0.91; P < 0.001). This is consistent with the definition of CDP, which is a functional parameter that includes both pressure and flow information.
Conclusions: CDP, a nondimensional parameter combining simultaneous measurements of pressure drop and velocity data, can accurately define the severity of coronary stenoses and could prove advantageous clinically.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.25085 | DOI Listing |
In this paper, we studied the diffusion characteristics and distribution patterns of gas leakage in soil from buried natural gas pipelines. The three-dimensional simulation model of buried natural gas pipeline leakage was established using Fluent software. Monitoring points of gas leakage mole fraction were set up at different locations, and the influence of buried depth and pressure factors on the mole fraction and diffusion of leaked gas was analyzed.
View Article and Find Full Text PDFSci Rep
December 2024
Jiangsu Key Laboratory of Oil-Gas Storage and Transportation Technology, Changzhou University, Changzhou, 213164, Jiangsu, China.
Bend pipe is a common part of long distance pipeline. There is very important to study the flow law of hydrate particles in the bend pipe, and pipeline design will be optimized. In addition, the efficiency and safety of pipeline gas transmission will be improved.
View Article and Find Full Text PDFJ Am Med Dir Assoc
December 2024
Division of Geriatrics, University of Health Sciences, Gulhane Faculty of Medicine and Gulhane Training and Research Hospital, Ankara, Türkiye. Electronic address:
Objectives: Frailty has been shown to be linked with orthostatic hypotension (OH) in older adults, but the role of anticholinergic drugs in this relationship never has been explored. The purpose of this was to examine the relationship between anticholinergic burden (ACB) and OH in frail older adults living in the community and to examine whether this association differs according to polypharmacy.
Design: A cross-sectional study.
Sci Rep
December 2024
Department of Mechanical Engineering, Qom University of Technology, Qom, 37195-1519, Iran.
This study investigates the use of multi-layered porous media (MLPM) to enhance thermal energy transfer within a counterflow double-pipe heat exchanger (DPHE). We conducted computational fluid dynamics (CFD) simulations on DPHEs featuring five distinct MLPM configurations, analyzed under both fully filled and partially filled conditions, alongside a conventional DPHE. The impact of various parameters such as porous layer arrangements, thickness, and flow Reynolds numbers on pressure drop, logarithmic mean temperature difference (LMTD), and performance evaluation criterion (PEC) was assessed.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.
Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.