Objective: The recommended daily intakes of vitamin D according to the recent Clinical Practice Guideline (CPG) of the Endocrine Society are three- to fivefold higher than the Institute of Medicine (IOM) report. We speculated that these differences could be explained by different mathematical approaches to the vitamin D dose response.
Methods: Studies were selected if the daily dose was ≤2000 IU/day, the duration exceeded 3 months, and 25-hydroxyvitamin D (25OHD) concentrations were measured at baseline and post-therapy. The rate constant was estimated according to the CPG approach. The achieved 25OHD result was estimated according to the following: i) the regression equation approach of the IOM; ii) the regression approach of the Vitamin D Supplementation in Older Subjects (ViDOS) study; and iii) the CPG approach using a rate constant of 2.5 (CPG2.5) and a rate constant of 5.0 (CPG5.0). The difference between the expected and the observed 25OHD result was expressed as a percentage of observed and analyzed for significance against a value of 0% for the four groups.
Results: Forty-one studies were analyzed. The mean (95% CI) rate constant was 5.3 (4.4-6.2) nmol/l per 100 IU per day, on average twofold higher than the CPG rate constant. The mean (95% CI) for the difference between the expected and observed expressed as a percentage of observed was as follows: i) IOM, -7 (-16,+2)% (t=1.64, P=0.110); ii) ViDOS, +2 (-8,+12)% (t=0.40, P=0.69); iii) CPG2.5, -21 (-27,-15)% (t=7.2, P<0.0001); and iv) CPG5.0+3 (-4,+10)% (t=0.91, P=0.366).
Conclusion: The CPG 'rule of thumb' should be doubled to 5.0 nmol/l (2.0 ng/ml) per 100 IU per day, adopting a more risk-averse position.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3680954 | PMC |
http://dx.doi.org/10.1530/EC-13-0008 | DOI Listing |
Biomed Phys Eng Express
January 2025
Brain Health Imaging Centre, Centre for Addiction and Mental Health, B68-250 College St, Toronto, Ontario, M5T 1R8, CANADA.
Objective: Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.
View Article and Find Full Text PDFPLoS One
January 2025
North China University of Water Resources and Electric Power, Zhengzhou City, Henan Province, P.R. China.
This study employs electrical resistivity tomography (ERT) to experimentally investigate the migration characteristics of light non-aqueous phase liquids (LNAPL) under various groundwater conditions. Through cross-hole measurements and time-lapse inversion, the migration process of LNAPL under three scenarios-unsaturated conditions, constant groundwater levels, and declining water levels-was systematically analyzed. The results indicate that LNAPL migration behavior exhibits significant differences under different conditions.
View Article and Find Full Text PDFStat Med
February 2025
Department of Statistics and Data Science, National University of Singapore, Singapore, Singapore.
The additive hazard model, which focuses on risk differences rather than risk ratios, has been widely applied in practice. In this paper, we consider an additive hazard model with varying coefficients to analyze recurrent events data. The model allows for both varying and constant coefficients.
View Article and Find Full Text PDFBiol Cybern
January 2025
Institute for Physics and Astronomy, University of Potsdam, Karl-Liebknecht-Str. 24-25, 14476, Potsdam, Germany.
Piecewise-deterministic Markov processes combine continuous in time dynamics with jump events, the rates of which generally depend on the continuous variables and thus are not constants. This leads to a problem in a Monte-Carlo simulation of such a system, where, at each step, one must find the time instant of the next event. The latter is determined by an integral equation and usually is rather slow in numerical implementation.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Chair of Modelling in Engineering Sciences and Medicine, Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva c. 6, 1000 Ljubljana, Slovenia.
The Lateral Collateral Ligament (LCL), one of the four major ligaments in the knee joint, resides on the outer aspect of the knee. It forms a vital connection between the femur and the fibula. The LCL's primary role is to provide stability against Varus forces, safeguarding the knee from undue rotation and tibial displacement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!