Image-guided robotic interventions for prostate cancer.

Nat Rev Urol

Department of Surgery & Cancer, Imperial College London, 10th Floor QEQM Building, St Mary's Hospital, Praed Street, London W2 1NY, UK.

Published: August 2013

Robotic prostatectomy is a common surgical treatment for men with prostate cancer, with some studies estimating that 80% of prostatectomies now performed in the USA are done so robotically. Despite the technical advantages offered by robotic systems, functional and oncological outcomes of prostatectomy can still be improved further. Alternative minimally invasive treatments that have also adopted robotic platforms include brachytherapy and high-intensity focused ultrasonography (HIFU). These techniques require real-time image guidance--such as ultrasonography or MRI--to be truly effective; issues with software compatibility as well as image registration and tracking currently limit such technologies. However, image-guided robotics is a fast-growing area of research that combines the improved ergonomics of robotic systems with the improved visualization of modern imaging modalities. Although the benefits of a real-time image-guided robotic system to improve the precision of surgical interventions are being realized, the clinical usefulness of many of these systems remains to be seen.

Download full-text PDF

Source
http://dx.doi.org/10.1038/nrurol.2013.129DOI Listing

Publication Analysis

Top Keywords

image-guided robotic
8
prostate cancer
8
robotic systems
8
robotic
5
robotic interventions
4
interventions prostate
4
cancer robotic
4
robotic prostatectomy
4
prostatectomy common
4
common surgical
4

Similar Publications

Towards transcervical ultrasound-guided transoral robotic surgery.

Oral Oncol

January 2025

Division of Otolaryngology-Head & Neck Surgery, Department of Surgery, University of British Columbia, Canada. Electronic address:

Background: In the context of transoral robotic surgery (TORS) for oropharyngeal squamous carcinoma (OPSCC), preoperative imaging and intraoperative visualization plays a pivotal role in optimizing resection margins. Prior work has demonstrated the ability of transoral ultrasound (US) in identifying OPSCC margins and vascular structures. This study evaluates the effectiveness of transcervical ultrasound (TUS), as well as other preoperative imaging modalities, in evaluating OPSCC volumes and compares this to post TORS pathological OPSCC volumes.

View Article and Find Full Text PDF

Objective: To maximize local tumor control, stabilize affected bones, and preserve or replace joints with minimal interventional burden, thereby enhancing quality of life for empowered living.

Indications: Suitable for patients with bone metastases, particularly those with severe pain and/or fractures and appropriate life expectancy.

Contraindications: In primary bone tumors, refer to the sarcoma surgery team for evaluation of wide resection.

View Article and Find Full Text PDF

Background: Percutaneous puncture procedures, guided by image-guided robotic-assisted intervention (IGRI) systems, are susceptible to disruptions in patients' respiratory rhythm due to factors such as pain and psychological distress.

Methods: We developed an IGRI system with a coded structured light camera and a binocular camera. Our system incorporates dual-pathway deep learning networks, combining convolutional long short-term memory (ConvLSTM) and point long short-term memory (PointLSTM) modules for real-time respiratory signal monitoring.

View Article and Find Full Text PDF

Background: In order to achieve spatial registration for surgical navigation, a spatial registration method based on point cloud and deep learning is proposed.

Methods: Neural networks are used to register medical image point clouds and patient surface point clouds to complete spatial registration of surgical navigation. An image processing method is designed to convert medical images into point clouds, and a structured light robot is used to extract patient surface point clouds.

View Article and Find Full Text PDF

Tissue-probe contact assessment during robotic surgery using single-fiber reflectance spectroscopy.

Biomed Opt Express

December 2024

Image-Guided Surgery, Department of Surgery, the Netherlands Cancer Institute-Antoni van Leeuwenhoek, Plesmanlaan 121, Postbus 90203, 1066 CX Amsterdam, The Netherlands.

The introduction of robotic surgery has improved minimally invasive surgery, and now robotic surgery is used in several areas of surgical oncology. Several optical techniques can be used to discriminate cancer from healthy tissue based on their optical properties. These technologies can also be employed with a small fiber-optic probe during minimally invasive surgery; however, for acquiring reliable measurements, some optical techniques require the fiber-optic probe to be in direct contact with the tissue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!