A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determining the precision of dual energy x-ray absorptiometry and bioelectric impedance spectroscopy in the assessment of breast cancer-related lymphedema. | LitMetric

Background: The composition of breast cancer-related lymphedema (BCRL) has been shown to evolve from the initial accumulation of fluid to the development of fibrotic lesions and abnormal fat deposition. Therefore, precise and reliable assessments of BCRL are required to develop accurate staging and management. Although dual energy x-ray absorptiometry (DXA) and bioelectric impedance spectroscopy (BIS) have been used to assess BCRL, no study has evaluated the precision of these two modalities in the same cohort.

Methods And Results: We determined the precision of DXA and BIS in lymphedematous (LE) and nonaffected (NA) arms of 24 women with Stage II unilateral BCRL. Precision was calculated from the results of paired bilateral arm measurements obtained from DXA scans measuring fat, lean, and bone mineral masses, BIS measuring extracellular fluid (ECF) and total fluid volume, and circumferential tape measurements (CM) of the arms to calculate the anatomic volume. Precision error was expressed as the root mean square (RMS) of the coefficients of variation (%CV) and standard deviations (SD).

Results: The precisions of DXA and BIS varied from 1.16% (DXA measurements of LE arm total volume) to 1.86% (BIS LE arm total fluid volume) and from 0.95% (DXA lean mass of NA arm) to 1.72% (DXA BMC of NA arm). Precision of CM measures of arm volume were 1.71% CV for LE arm and 2.51% CV for NA arm. The fat and lean masses of the LE arm exceeded the NA arm by about 15% (p<0.0001). ECF and total fluid volume of LE arm was 22.6% and 19% greater than the NA arm (p<0.0001), respectively.

Conclusion: For BCRL, these findings suggest that DXA and BIS are two measurement instruments that provide acceptable levels of precision for the measurement of arm lean mass, fat mass and ECF volume, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1089/lrb.2012.0020DOI Listing

Publication Analysis

Top Keywords

arm
10
dual energy
8
energy x-ray
8
x-ray absorptiometry
8
bioelectric impedance
8
impedance spectroscopy
8
breast cancer-related
8
cancer-related lymphedema
8
dxa bis
8
fat lean
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!