Treatment of intractable pneumothorax with emphysema using endobronchial watanabe spigots.

Korean J Thorac Cardiovasc Surg

Department of Thoracic and Cardiovascular Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Korea.

Published: June 2013

Prolonged air leakage is a major cause of morbidity in pneumothorax. When conservative management is not effective, surgery should be performed. However, surgery is not appropriate in patients with low pulmonary function. In these patients, occlusion of the airway with endobronchial blockers may be attempted under bronchoscopy. We treated two patients with prolonged air leakage using endobronchial Watanabe spigots under fibrobronchoscopy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3680612PMC
http://dx.doi.org/10.5090/kjtcs.2013.46.3.226DOI Listing

Publication Analysis

Top Keywords

endobronchial watanabe
8
watanabe spigots
8
prolonged air
8
air leakage
8
treatment intractable
4
intractable pneumothorax
4
pneumothorax emphysema
4
emphysema endobronchial
4
spigots prolonged
4
leakage major
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?