Simultaneous EEG-fMRI allows the excellent temporal resolution of EEG to be combined with the high spatial accuracy of fMRI. The data from these two modalities can be combined in a number of ways, but all rely on the acquisition of high quality EEG and fMRI data. EEG data acquired during simultaneous fMRI are affected by several artifacts, including the gradient artefact (due to the changing magnetic field gradients required for fMRI), the pulse artefact (linked to the cardiac cycle) and movement artifacts (resulting from movements in the strong magnetic field of the scanner, and muscle activity). Post-processing methods for successfully correcting the gradient and pulse artifacts require a number of criteria to be satisfied during data acquisition. Minimizing head motion during EEG-fMRI is also imperative for limiting the generation of artifacts. Interactions between the radio frequency (RF) pulses required for MRI and the EEG hardware may occur and can cause heating. This is only a significant risk if safety guidelines are not satisfied. Hardware design and set-up, as well as careful selection of which MR sequences are run with the EEG hardware present must therefore be considered. The above issues highlight the importance of the choice of the experimental protocol employed when performing a simultaneous EEG-fMRI experiment. Based on previous research we describe an optimal experimental set-up. This provides high quality EEG data during simultaneous fMRI when using commercial EEG and fMRI systems, with safety risks to the subject minimized. We demonstrate this set-up in an EEG-fMRI experiment using a simple visual stimulus. However, much more complex stimuli can be used. Here we show the EEG-fMRI set-up using a Brain Products GmbH (Gilching, Germany) MRplus, 32 channel EEG system in conjunction with a Philips Achieva (Best, Netherlands) 3T MR scanner, although many of the techniques are transferable to other systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3725697PMC
http://dx.doi.org/10.3791/50283DOI Listing

Publication Analysis

Top Keywords

high quality
12
quality eeg
12
eeg data
12
simultaneous fmri
12
eeg
9
data simultaneous
8
simultaneous eeg-fmri
8
fmri data
8
eeg fmri
8
magnetic field
8

Similar Publications

Crystalline Covalent Triazine Frameworks and 2D Triazine Polymers: Synthesis and Applications.

Acc Chem Res

January 2025

School of Engineering, Westlake University, Hangzhou 310024, Zhejiang Province, China.

ConspectusCovalent triazine frameworks (CTFs) are a novel class of nitrogen-rich conjugated porous organic materials constructed by robust and functional triazine linkages, which possess unique structures and excellent physicochemical properties. They have demonstrated broad application prospects in gas/molecular adsorption and separation, catalysis, energy conversion and storage, etc. In particular, crystalline CTFs with well-defined periodic molecular network structures and regular pore channels can maximize the utilization of the features of CTFs and promote a deep understanding of the structure-property relationship.

View Article and Find Full Text PDF

Intravascular Imaging as a Performance Measure for Percutaneous Coronary Intervention.

Circ Cardiovasc Interv

January 2025

Division of Cardiology, Department of Medicine, University of Washington Medical Center, Seattle (E.J.S., T. Salahuddin, J.A.D.).

Background: Intravascular imaging (IVI) is widely recognized to improve outcomes after percutaneous coronary intervention (PCI). However, IVI is underutilized and is not yet established as a performance measure for quality PCI.

Methods: We examined temporal trends of IVI use for all PCIs performed at Veterans Affairs hospitals in the United States from 2010 to 2022 using retrospective observational cohorts.

View Article and Find Full Text PDF

Despite an increasing number of studies examining the effect of Single-Photon Emission Computed Tomography/ Computed Tomography (SPECT/CT) on improvement of diagnosis of aseptic loosening, there is still a great deal of uncertainty regarding its applicability in diagnostic algorithm. Therefore, in this meta-analysis, we aimed to investigate the diagnostic performance of SPECT/CT for identification of aseptic loosening in patients with persistent pain following the total knee arthroplasty (TKA) and total hip arthroplasty (THA). Electronic databases including Medline, Scopus, Web of Science, Cochrane library, and Embase were systematically searched for identifying relevant published studies from their inception to April 2023.

View Article and Find Full Text PDF

Abstinence self-efficacy, belief in one's ability to abstain, has been identified as a predictor of substance use behavior change. Yet, many people who use substances do not want to abstain. Self-efficacy for achieving a range of goals (i.

View Article and Find Full Text PDF

With the rising demand of saffron, it is essential to standardize the confirmation of its origin and identify any adulteration to maintain a good quality led market product. However, a rapid and reliable strategy for identifying the adulteration saffron is still lacks. Herein, a combination of headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS) and convolutional neural network (CNN) was developed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!