A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. | LitMetric

Introduction: Following a chemical, biological, radiation and nuclear (CBRN) incident, prompt establishment of an advanced airway is required for patients with respiratory failure within the warm zone, while wearing personal protective equipment (PPE). Previous studies reported that intubation attempts were prolonged, and incidence of esophageal intubation was increased with conventional Macintosh laryngoscope (McL), while wearing CBRN-PPE. Pentax-AWS (AWS), a recently introduced portable video laryngoscope, was compared with the McL to test its utility for tracheal intubation while wearing CBRN-PPE.

Methods: 31 participants performed unsuited and suited intubations on an advanced life support simulator. The sequence of intubating devices and PPE wearing were randomised. Time to complete tracheal intubation (primary end point), time to see the vocal cords, overall success rate, percentage of glottic opening, dental compression and ease of intubation were measured.

Results: Suited intubations required significantly longer time to complete intubation than unsuited intubations, in both McL and AWS (22.2 vs 26.4 s, 14.2 vs 18.2 s, respectively). However, suited AWS intubations required shorter time to complete tracheal intubation than unsuited McL intubations (18.2 vs 22.2 s). In secondary outcomes, moreover, suited intubations using the AWS compared favourably with unsuited intubations using the McL.

Conclusions: Although the CBRN-PPE adversely affected time required to complete tracheal intubation with the AWS, suited intubations using the AWS were even superior to unsuited intubations using the McL. The AWS should be a promising device to perform tracheal intubation while wearing the CBRN-PPE.

Download full-text PDF

Source
http://dx.doi.org/10.1136/emermed-2012-201463DOI Listing

Publication Analysis

Top Keywords

tracheal intubation
24
suited intubations
16
intubation wearing
12
time complete
12
complete tracheal
12
unsuited intubations
12
intubation
10
intubations
9
chemical biological
8
biological radiation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!