A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Thirty-seven patients treated with the C-seal: protection of stapled colorectal anastomoses with a biodegradable sheath. | LitMetric

Thirty-seven patients treated with the C-seal: protection of stapled colorectal anastomoses with a biodegradable sheath.

Int J Colorectal Dis

Department of Surgery, Division of Abdominal Surgery, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700 RB, Groningen, The Netherlands.

Published: October 2013

Purpose: The present study was performed to get a better insight in the incidence of anastomotic leakage leading to reintervention when using the C-seal: a biodegradable sheath that protects the stapled colorectal anastomosis from leakage.

Methods: The C-seal is a thin walled tube-like sheath that forms a protective sheath within the bowel lumen. Thirty-seven patients undergoing surgery with creation of a stapled colorectal anastomosis with C-seal were analyzed. Follow-up was completed until 3 months after surgery.

Results: One patient (3%) developed anastomotic leakage leading to reintervention. None of the 37 anastomoses was dismantled. One patient was diagnosed with a rectovaginal fistula. In three patients (8%), a perianastomotic abscess spontaneously drained.

Conclusion: The incidence of anastomotic leakage leading to reintervention when using the C-seal (3%) is lower than expected based on the literature (11%). We have currently set-up a multicenter randomized trial to confirm the efficiency of the C-seal (www.csealtrial.nl).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3778980PMC
http://dx.doi.org/10.1007/s00384-013-1724-7DOI Listing

Publication Analysis

Top Keywords

stapled colorectal
12
anastomotic leakage
12
leakage leading
12
leading reintervention
12
thirty-seven patients
8
biodegradable sheath
8
incidence anastomotic
8
reintervention c-seal
8
colorectal anastomosis
8
c-seal
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!