Resonant scattering and diffraction beamline P09 at PETRA III.

J Synchrotron Radiat

Deutsches Elektronen-Synchrotron (DESY), 22603 Hamburg, Germany.

Published: July 2013

The resonant scattering and diffraction beamline P09 at PETRA III is designed for X-ray experiments requiring small beams, energy tunability, variable polarization and high photon flux. It is highly flexible in terms of beam size and offers full higher harmonic suppression. A state-of-the-art double phase-retarder set-up provides variable linear or circular polarization. A high-precision Psi-diffractometer and a heavy-load diffractometer in horizontal Psi-geometry allow the accommodation of a wide variety of sample environments. A 14 T cryo-magnet is available for scattering experiments in magnetic fields.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049513009011DOI Listing

Publication Analysis

Top Keywords

resonant scattering
8
scattering diffraction
8
diffraction beamline
8
beamline p09
8
p09 petra
8
petra iii
8
iii resonant
4
iii designed
4
designed x-ray
4
x-ray experiments
4

Similar Publications

ISB 1442 is a bispecific biparatopic antibody in clinical development to treat hematological malignancies. It consists of two adjacent anti-CD38 arms targeting non-overlapping epitopes that preferentially drive binding to tumor cells and a low-affinity anti-CD47 arm to enable avidity-induced blocking of proximal CD47 receptors. We previously reported the pharmacology of ISB 1442, designed to reestablish synthetic immunity in CD38+ hematological malignancies.

View Article and Find Full Text PDF

Methane (CH), which is the main component of natural gas, is an abundant and widely available carbon resource. However, CH has a low energy density of only 36 kJ L under ambient conditions, which is significantly lower than that of gasoline (. 34 MJ L).

View Article and Find Full Text PDF

Langerhans cell histiocytosis in children: the value of ultrasound in diagnosis and follow-up.

BMC Med Imaging

January 2025

Department of Ultrasound Medicine, First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, China.

Background: Langerhans cell histiocytosis (LCH) is a rare disease, most prevalent in children. Ultrasound is a noninvasive, cheap, and widely available technique. However, systematic elucidation of sonographic features of LCH and treatment related follow-up are relatively few, resulting in overall underestimation of the clinical value of ultrasound in diagnosing and monitoring LCH.

View Article and Find Full Text PDF

We experimentally study cosmological particle production in a two-dimensional Bose-Einstein condensate, whose density excitations map to an analog cosmology. The expansion of spacetime is realized with tunable interactions. The particle spectrum can be understood through an analogy to quantum mechanical scattering, in which the dynamics of the spacetime metric determine the shape of the scattering potential.

View Article and Find Full Text PDF

Electronic quenching of sulfur induced by argon collisions.

Phys Chem Chem Phys

January 2025

Univ Rennes, CNRS, IPR (Institut de Physique de Rennes) - UMR 6251, F-35000 Rennes, France.

An accurate potential energy model, explicitly designed for studying scattering and treating the spin-orbit and nonadiabatic couplings on an equal footing, is proposed for the S + Ar system. The model is based on the Effective Relativistic Coupling by Asymptotic Representation (ERCAR) approach, building the geometry dependence of the spin-orbit interaction a diabatisation scheme. The resulting full diabatic model is used in close-coupling calculations to compute inelastic scattering cross sections for de-excitation from the S(D) fine structure level into the P multiplet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!