Determination of the antiretroviral drug acyclovir in diluted alkaline electrolyte by adsorptive stripping voltammetry at the mercury film electrode.

Anal Chem Insights

Department of Chemistry, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, RJ, Brazil. ; Facultad de Quimica, Química Analítica, Universidad de La Habana, Cuba.

Published: June 2013

This paper describes a stripping method for the determination of acyclovir at the submicromolar concentration level. This method is based on controlled adsorptive accumulation of acyclovir at thin-film mercury electrode, followed by a linear cyclic scan voltammetry measurement of the surface species. Optimal experimental conditions include a NaOH solution of 2.0 × 10(-3) mol L(-1) (supporting electrolyte), an accumulation potential of -0.40 V, and a scan rate of 100 mV s(-1). The response of acyclovir is linear over the concentration range 0.02 to 0.12 ppm. For an accumulation time of 4 minutes, the detection limit was found to be 0.42 ppb (1.0 × 10(-9) mol L(-1)). More convenient methods to measure the acyclovir in presence of the didanosine, efavirenz, nevirapine, nelfinavir, lamivudine, and zidovudine were also investigated. The utility of this method is demonstrated by the presence of acyclovir together with Adenosine triphosphate (ATP) or DNA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666987PMC
http://dx.doi.org/10.4137/ACI.S11608DOI Listing

Publication Analysis

Top Keywords

mol l-1
8
acyclovir
6
determination antiretroviral
4
antiretroviral drug
4
drug acyclovir
4
acyclovir diluted
4
diluted alkaline
4
alkaline electrolyte
4
electrolyte adsorptive
4
adsorptive stripping
4

Similar Publications

Citrullus lanatus is an important vegetable crop, but it is heavily polluted by cadmium. In this study, we used C. Lanatus as experimental material to investigate effects of different concentrations (0, 50, 100, 200, 400 µmolL) of exogenous melatonin, and grafting on the physiological growth index and anatomical structure of seedlings were studied by simulating Cd (180 mg L) stress environment.

View Article and Find Full Text PDF

A paper-based SERS/colorimetry substrate for reliable detection.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, PR China. Electronic address:

For on-site analysis, the combination of surface enhanced Raman scattering (SERS) and colorimetry, as a dual-mode detection, can effectively improve the accuracy of detection, and reduce the influence of instrument fluctuation, which greatly improves the accuracy and reliability of the results. However, the preparation of SERS/colorimetry substrates are usually time-consuming and costly, which limits their practical applications. In this paper, a hydrophobic paper-based SERS/colorimetry substrate can be prepared by a simple spraying method.

View Article and Find Full Text PDF

Hypertension and dyslipidemia are two of the most frequently co-occurring cardiovascular risk factors. The combined regimen of hydrochlorothiazide (HCTZ), rosuvastatin (ROS), and losartan (LOS) helped in the successful management of both conditions. This work's objective is to develop an eco-friendly, sensitive, simple, and reliable chromatographic method for the simultaneous estimation of HCTZ, ROS, and the LOS ternary mixture in their pure form, and pharmaceutical formulations.

View Article and Find Full Text PDF

Achieving a net-zero emissions economy requires significant decarbonization of the transportation sector, which depends on the development of highly efficient electrocatalysts. Electrolytic water splitting is a promising approach to this end, with Ni-Mo alloys emerging as strong candidates for hydrogen production catalysts. This study investigates the electrodeposition of Ni and Ni-Mo nanostructured alloys with high molybdenum content onto low-carbon steel cathodes using a novel alkaline green lactate bath.

View Article and Find Full Text PDF

Indocyanine green dyed gauze-guided minimum invasive surgery for anatomical landmarks and preventing gauze remnants: a pilot study.

Langenbecks Arch Surg

January 2025

Department of Chemical Science & Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8552, Japan.

Purpose: We aimed to develop a novel fluorescent surgical gauze dyed with indocyanine green (ICG) to guide surgeons to the target anatomical destination during surgery for real-time navigation and to prevent gauze remnants after surgery.

Methods: Surgical gauze was dyed with an aqueous solution of ICG (5.0 × 10 mol L for Steraze, 1.

View Article and Find Full Text PDF