Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases.

J Orthop Trauma

*Orthopaedic Trauma Service, Barnes-Jewish Hospital, Washington University School of Medicine, St Louis, MO; †Mayo Clinic, Rochester, MN; ‡Orthopaedic Trauma Institute, University of California San Francisco, San Francisco General Hospital, San Francisco, CA; §Harris Methodist Fort Worth Hospital, John Peter Smith Orthopaedic Surgery Residency Program, Fort Worth, TX; and ‖Department of Orthopaedics, Harborview Medical Center, Seattle, WA.

Published: February 2014

Objectives: Locked plating has become a standard method to treat supracondylar femur fractures. Emerging evidence indicates that this method of treatment is associated with modest failure rates. The goals of this study were to determine risk factors for complications and to provide technical recommendations for locked plating of supracondylar femur fractures.

Design: Retrospective review.

Setting: Three level I or II trauma centers.

Patients/participants: Three hundred twenty-six patients with 335 distal femur fractures (OTA 33A or C, 33% open) treated with lateral locked plates were studied. The average patient age was 57 years (range 17-97 years), 55% were women, 34% were obese, 19% were diabetic, and 24% were smokers.

Intervention: All patients were managed with open reduction internal fixation using a lateral distal femoral locked plate construct that included locked screws in the distal fragment and nonlocked, locked, or a combination of locked and nonlocked screws in the proximal fragment.

Main Outcome Measurements: Risk factors for reoperation to promote union, deep infection, and implant failure.

Results: After the index procedure, 64 fractures (19%) required reoperation to promote union, including 30 that had a planned staged bone grafting because of the metaphyseal defect after debridement of an open fracture. Independent risk factors for reoperation to promote union and deep infection included diabetes and open fracture. Risk factors for proximal implant failure included open fracture, smoking, increased body mass index, and shorter plate length.

Conclusions: The identified risk factors for reoperation to promote union and complications included open fracture, diabetes, smoking, increased body mass index, and shorter plate length. Most factors are out of surgeon control but are useful when considering prognosis. Use of relatively long plates is a technical factor that can reduce risk for fixation failure.

Level Of Evidence: Prognostic level II. See instructions for authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0b013e31829e6dd0DOI Listing

Publication Analysis

Top Keywords

risk factors
24
reoperation promote
16
promote union
16
open fracture
16
femur fractures
12
factors reoperation
12
locked
8
locked plate
8
distal femur
8
locked plating
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!