Background: Insulin bolusing calculators alleviate the burden of having to calculate insulin bolus doses for patients with type 1 diabetes mellitus (T1DM). Three important pieces of information are needed: a blood glucose monitoring (BGM) result, carbohydrates to be consumed, and the amount of insulin bolus delivered. The purpose of this study was to describe insulin pump adherence behaviors associated with the use of bolus calculators in youth who use Medtronic insulin pumps.

Methods: Data were downloaded from the MiniMed Paradigm insulin pumps (Medtronic) of 31 youth with T1DM. Areas of adherence that were evaluated included fundamental insulin pump adherence behaviors (e.g., BGM, carbohydrate entry, and insulin bolusing), decisions about Wizard® recommendations, and three Wizard steps: BGM result-carbohydrate input-insulin bolus.

Results: On average, patients conducted BGM ≥4 times/day on 69% of days, inputted carbohydrates ≥3 times/day on 63% of days, and insulin bolused ≥3 times/day on 85% of days. Participants generally followed Wizard recommendations. Finally, participants completed all three Wizard steps (BGM, carbohydrate input, insulin bolus) within 30 min for an average of 29% of boluses. Almost 3% of boluses that were preceded by Wizard use were delivered without conducting BGM or inputting carbohydrates.

Conclusion: There was substantial variability in insulin pump adherence behaviors (e.g., days when no BGM occurred, reliance on basal insulin). Interventions targeting insulin pump adherence behaviors have the potential to optimize diabetes health outcomes and glycemic control. Improving insulin pump software reports is one promising avenue for improving adherence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3869132PMC
http://dx.doi.org/10.1177/193229681300700309DOI Listing

Publication Analysis

Top Keywords

insulin pump
20
pump adherence
16
adherence behaviors
16
insulin
15
insulin bolusing
12
insulin bolus
12
potential optimize
8
health outcomes
8
type diabetes
8
diabetes mellitus
8

Similar Publications

Background: Insulin resistance (IR) is associated with abnormal tau-phosphorylation and IR markers in AD brain co-localize with neurofibrillary tangles. One strategy to overcome brain IR is to increase brain insulin is via intranasal insulin (INI) administration using specialized intranasal devices that deliver insulin to the brain. Our recent INI vs.

View Article and Find Full Text PDF

Background: Insulin resistance (IR) is associated with abnormal tau-phosphorylation and IR markers in AD brain co-localize with neurofibrillary tangles. One strategy to overcome brain IR is to increase brain insulin is via intranasal insulin (INI) administration using specialized intranasal devices that deliver insulin to the brain. Our recent INI vs.

View Article and Find Full Text PDF

Approach to the Patient using Diabetes Technology in Pregnancy.

J Clin Endocrinol Metab

January 2025

Section of Maternal Fetal Medicine, Obstetrics and Gynecology, University of Chicago.

Diabetes in pregnancy increases risk for complications for the pregnant patient and neonate. Tight glycemic control to maintain glucose levels as close to non-diabetic ranges as possible can lower risk for these complications. Achieving strict glycemic targets can be challenging and technologies including continuous glucose monitors (CGM) and hybrid closed loop (HCL) insulin pumps have the potential to improve diabetes control and pregnancy outcomes.

View Article and Find Full Text PDF

Fear of hypoglycemia and sleep in children with type 1 diabetes and their parents.

Front Endocrinol (Lausanne)

December 2024

Department of Pediatric Diabetes and Endocrinology, Clinique Pédiatrique, Centre Hospitalier, Luxembourg, Luxembourg.

Aims: To compare impact of pump treatment and continuous glucose monitoring (CGM) with predictive low glucose suspend (SmartGuard) or user initiated CGM (iscCGM) on sleep and hypoglycemia fear in children with type 1 Diabetes and parents.

Methods: Secondary analysis of data from 5 weeks pump treatment with iscCGM (A) or SmartGuard (B) open label, single center, randomized cross-over study was performed. At baseline and end of treatment arms, sleep and fear of hypoglycemia were evaluated using ActiGraph and questionnaires.

View Article and Find Full Text PDF

Background: Insulin pumps coupled with continuous glucose monitoring sensors use algorithms to analyze real-time blood glucose levels. This allows for the suspension of insulin administration before hypoglycemic thresholds are reached or for adaptive tuning in hybrid closed-loop systems. This longitudinal retrospective study aims to analyze real-world glycemic outcomes in a pediatric population transitioning to such devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!