Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We tested the clinically relevant diagnostic accuracy of a new electrocardiographic (ECG) recording system incorporating all 10 ECG electrodes in a single-size glove worn on the patient's left arm and placed on the chest. The PhysioGlove (PG) was designed to allow fast, reproducible, electrode placement with only minimal training. The American College of Cardiology/American Heart Association ECG recording guidelines and others have repeatedly highlighted the unacceptable progressive deterioration in ECG accuracy mainly resulting from a performer's lack of proficiency and diligence, leading to frequent electrode misplacement. We studied 428 consenting adult patients with a broad spectrum of anthropomorphic characteristics and ECG and cardiovascular pathologic entities. The chest girth was measured to ascertain the single-size PG clinical diagnostic accuracy in ≥90% of this patient population. For each patient, a PG and standard-cable electrocardiogram were consecutively recorded and interpreted by experienced electrocardiographers. The study included 3 phases: phase 1, run-in (n = 120); phase 2, comparative diagnostic accuracy (n = 208); and phase 3, randomized, blinded, diagnostic accuracy (n = 100). Of the entire study population (n = 428), 92% fit the chest girth range of 85 to 118 cm (34 to 47 in.), representing the reference standard clinical diagnostic PG chest girth range. The phase 2 PG diagnostic accuracy was 91.3% for entire chest girth range and 95.7% for the 89.4% of patients with a chest girth within the reference range. The mean PG diagnostic accuracy in phase 3 was 93% (95% confidence interval 89% to 95%). In conclusion, compared with standard-cable electrocardiograms, the PG demonstrated excellent diagnostic accuracy (93% to 95.7%) in ≥90% of a typical western adult patient population. The PG's ease of use and minimal training requirements offer a promising tool to markedly improve ECG clinical diagnostic accuracy in most adult western patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2013.05.018 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!