Purpose: The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns.

Materials And Methods: Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a 45° angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position.

Results: In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased.

Conclusion: This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675293PMC
http://dx.doi.org/10.4047/jap.2013.5.2.187DOI Listing

Publication Analysis

Top Keywords

shoulder region
16
core designs
8
designs stress
8
stress distribution
8
finite element
8
shoulder
8
masticatory force
8
maximum bite
8
bite force
8
loading points
8

Similar Publications

Reverse Hill-Sachs lesions (RHSL) are common complications associated with posterior shoulder dislocations and represent a significant challenge for preserving joint stability and function. If untreated, these compression fractures of the anteromedial humeral head can compromise the integrity of the joint, predisposing patients to recurrent instability and arthropathy. While various treatment modalities exist, achieving an anatomic reduction of the defect while preserving the articular cartilage remains a desirable outcome, particularly in acute settings.

View Article and Find Full Text PDF

Parsonage-Turner syndrome (PTS) is a rare brachial plexus neuropathy with a sudden onset of upper extremity pain, weakness, and loss of range of motion (ROM). Studies on occupational therapy (OT) interventions are limited. The aim of this case report was to explore the OT experiences, interventions, and outcomes of a patient with PTS.

View Article and Find Full Text PDF

Background: The importance of the subscapularis for reverse total shoulder arthroplasty has been demonstrated, especially for internal rotation and stability. In a deltopectoral approach, a detachment of the subscapularis is performed (tenotomy, tuberosity peeling, or osteotomy), but the tendon is not always repairable at the end. When it is repaired, healing is obtained in only 40%-76% of the cases, with potential consequences for the outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!