A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a new index of mechanical ventilation weaning: the timed inspiratory effort. | LitMetric

Evaluation of a new index of mechanical ventilation weaning: the timed inspiratory effort.

J Intensive Care Med

Nephrology Division, Department of Medicine, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.

Published: January 2015

Purpose: The performance of most indices used to predict ventilator weaning outcomes remains below expectation. The purpose of this study was to evaluate a new weaning index, the timed inspiratory effort (TIE) index, which is based on the maximal inspiratory pressure and the occlusion time required to reach it.

Methods: This observational prospective study included patients undergoing mechanical ventilation. Patients ready to be weaned had their TIE index and 6 previously reported indices recorded. The primary end point was the overall predictive performance of the studied weaning indices (area under the receiver operating characteristic curves [AUCs]). The secondary end points were sensitivity, specificity, positive predictive value, and negative predictive value. P values <.05 were considered significant.

Results: From the 128 initially screened patients, the 103 patients selected for the study included 45 women and 58 men (mean age 60.8 ± 19.8 years). In all, 60 patients were weaned, 43 were not weaned, and 32 died during the study period. Tracheotomy was necessary in 61 patients. The mean duration of mechanical ventilation was 17.5 ± 17.3 days. The AUC of 3 weaning predictors (the TIE index, the integrative weaning index, and the frequency-to-tidal volume [f/Vt] ratio index) was higher than the other indices. The TIE index had the largest AUC.

Conclusion: The TIE index performed better than the best weaning indices used in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0885066613483265DOI Listing

Publication Analysis

Top Keywords

mechanical ventilation
8
weaning timed
8
timed inspiratory
8
inspiratory effort
8
evaluation mechanical
4
weaning
4
ventilation weaning
4
effort purpose
4
purpose performance
4
performance indices
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!