Purpose: To compare changes in peripheral refraction with single-vision (SV) and multifocal (MF) correction of distance central refraction with commercially available SV and MF soft contact lenses (SCLs) in young myopic adults.
Methods: Thirty-four myopic adult subjects were fitted with Proclear Sphere and Proclear Multifocal SCLs to correct their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with the two different types of SCL correction.
Results: At baseline, refraction was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared with center at 30 and 35 degrees in the temporal visual field (VF) in low myopes, and at 30 and 35 degrees in the temporal VF, and 10, 30, and 35 degrees in the nasal VF in moderate myopes. Single-vision and MF distance correction with Proclear Sphere and Proclear Multifocal SCLs, respectively, caused a hyperopic shift in refraction at all locations in the horizontal VF. Compared with SV correction, MF SCL correction caused a significant relative myopic shift at all locations in the nasal VF in both low and moderate myopes and also at 35 degrees in the temporal VF in moderate myopes.
Conclusions: Correction of central refractive error with SV and MF SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. Single-vision SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction to experience an absolute hyperopic defocus. Multifocal SCL correction resulted in a relative myopic shift in peripheral refraction compared with SV SCL correction. This myopic shift may explain recent reports of reduced myopia progression rates with MF SCL correction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0b013e3182990878 | DOI Listing |
Indian J Ophthalmol
December 2024
Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Intrascleral haptic fixation of intraocular lens (IOL) is an extremely useful technique to provide visual rehabilitation in eyes with inadequate capsular support. It requires exteriorization of haptics along with tucking of haptics in the scleral groove preferably and conventionally in the horizontal meridian. In eyes with large corneal diameter, there is difficulty in tucking enough length of the haptics into the intrascleral groove, carrying the risk of slippage of haptics and decentration of IOL.
View Article and Find Full Text PDFFront Neurosci
December 2024
School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China.
Purpose: This study evaluates differences in the visual field performance when wearing the Defocus Incorporated Multiple Segments (DIMS) spectacle lens compared to wearing a conventional single vision (SV) spectacle lens.
Methods: Twenty-one children aged 9-14 years with spherical equivalent refraction (SER) between -1.13D to -4.
Front Med (Lausanne)
December 2024
Department of Biopharmaceutics and Clinical Pharmacy, School of Pharmacy, The University of Jordan, Amman, Jordan.
This study investigated how normal corneal stromal profiles change with age, sex, and corrected intraocular pressure (IOP). A retrospective observational analytical study was conducted in Jordan, employing anterior segment spectral-domain optical coherence tomography AS-OCT, a measured corneal stromal thickness (CST) in 134 eyes across the central 6-mm corneal diameter. People between the ages of 18 and 79 were included, and the mean CST values were linked to age groups, IOP, and cis-gender populations, with the exclusion of certain eye conditions.
View Article and Find Full Text PDFJ Int Med Res
December 2024
Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
Objective: Peripheral refraction is associated with myopia development. Due to a varying prevalence of myopia across different ethnic groups, the aim of the present study was to investigate the peripheral refraction profile in an Arabic population.
Methods: Adults attending an optometry clinic were recruited into this cross-sectional study.
Asia Pac J Ophthalmol (Phila)
December 2024
The Primasia International Eye Research Institute of The Chinese University of Hong Kong (Shenzhen), Shenzhen, China. Electronic address:
Myopia has ever-rising prevalence in the past few decades globally. Its pathogenesis is still not adequately elucidated especially at the signal transduction level. For the environmental risk factors, there is a large body of fragmented knowledge about the visual inputs for accommodation, myopiagenesis and emmetropization, with the latter two being essentially local processes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!