Objectives: To investigate the impact of cover screw, resin embedment, and implant angulation on artifact of microcomputed tomography (micro-CT) scanning for implant.

Materials And Methods: A total of twelve implants were randomly divided into 4 groups: (i) implant only; (ii) implant with cover screw; (iii) implant with resin embedment; and (iv) implants with cover screw and resin embedment. Implants angulation at 0°, 45°, and 90° were scanned by micro-CT. Images were assessed, and the ratio of artifact volume to total volume (AV/TV) was calculated. A multiple regression analysis in stepwise model was used to determine the significance of different factors. One-way ANOVA was performed to identify which combination of factors could minimize the artifact.

Results: In the regression analysis, implant angulation was identified as the best predictor for artifact among the factors (P < 0.001). Resin embedment also had significant effect on artifact volume (P = 0.028), while cover screw had not (P > 0.05). Non-embedded implants with the axis parallel to X-ray source of micro-CT produced minimal artifact.

Conclusions: Implant angulation and resin embedment affected the artifact volume of micro-CT scanning for implant, while cover screw did not.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.12200DOI Listing

Publication Analysis

Top Keywords

cover screw
16
resin embedment
16
micro-ct scanning
12
implant angulation
12
screw resin
8
implant cover
8
embedment implants
8
artifact volume
8
regression analysis
8
implant
7

Similar Publications

Background: To minimize the risk of impaired osseointegration historically, it has been recommended to insert the implant into the bone (submerged implants) and to allow for submerged healing of 3-6 months in the lower and upper jaw, this conventional technique is advocated. The concept of nonsubmerged healing was introduced in 1988 in which gingival former was placed at the time of implant placement instead of cover screw. The treatment concept of nonsubmerged implant placement enables early implant loading, one surgical procedure only, and a reduced treatment period for the patients.

View Article and Find Full Text PDF

Filtering facepiece respirators (FFRs) are manufactured in discrete sizes, with some models being limited in relation to accommodating the fit of some sex and race combinations. This study presents the development of a custom-fit respiratory protective device (RPD) which conforms to a user's facial features and flexes and moves with facial movements during use. Our design also integrates a pressure-sensing network, which continuously monitors fit and will alert the user when the fit is compromised.

View Article and Find Full Text PDF

Titanium miniplates and screws are commonly used in the surgical management of dentofacial deformities. Despite the opinion of the biocompatibility of these bone fixations, some patients experience symptoms of chronic inflammation around titanium implants even many years after their application. The aim of this study was to examine the levels of cytokines, chemokines, and growth factors released from the maxilla and mandible periosteum surrounding titanium fixations 11 months after the implantation procedure.

View Article and Find Full Text PDF

Traumatic posterior atlantoaxial dislocation (TPAD) without an associated fracture is a rare and challenging spinal injury. This PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses)-compliant case-based systematic review and meta-analysis aimed to comprehensively explore TPAD, covering clinical presentation, diagnosis, treatment, and clinical and radiological outcomes. Following the presentation of a case of TPAD without an associated fracture, we conducted a systematic search of electronic databases, including Scopus, PubMed, and Web of Science, from inception through October 2023, without language restrictions.

View Article and Find Full Text PDF
Article Synopsis
  • * Materials and Methods: Twelve Ti and twelve Zr implants were placed in human mandibles with half simulated for bone graft loss. CBCT images were taken with varied MAR settings, and five evaluators assessed graft loss using a scoring system.
  • * Results: Using MAR on the OP300 unit improved diagnostic accuracy for both implant types, while extreme MAR mode on the Eagle 3D unit decreased accuracy. Overall, Ti implants showed higher diagnostic values than Zr implants.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!