A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[A biomechanical comparison of Acutrak headless compression screw and AO cannulated lag screw for the fixation of Hoffa fracture]. | LitMetric

Objective: To compare the stability, strength of Letenneur type I Hoffa fractures fixed by Acutrak headless compression screws and AO cannulated lag screws.

Methods: 12 models of Letenneur type I Hoffa fractures were randomly divided into 4 groups, which were fixed with two AO cannulated lag screws or Acutrak headless compression screws anteroposteriorly or posteroanteriorly. The stress between two fragments of all specimens was tested. Axial compression test, the cycle load test and the limit load test were successively performed in every specimen.

Results: In axial compression test, displacement of Acutrak headless compression screw groups was lower than that of AO cannulated lag screw anteroposteriorly (P < 0.05). The load to failure for Acutrak headless compression screw groups was higher than that of AO cannulated lag screws (P < 0.05), no matter in anteroposterior or posteroanterior direction.

Conclusion: The strength and stability of Letenneur type I Hoffa fractures fixeded with Acutrak headless compression screw were superior to those provided by AO cannulated lag screw. The direction of screw affects the initial stability for AO cannulated lag screw, other than Acutrak headless compression screw.

Download full-text PDF

Source

Publication Analysis

Top Keywords

acutrak headless
28
headless compression
28
cannulated lag
28
compression screw
20
lag screw
16
letenneur type
12
type hoffa
12
hoffa fractures
12
screw
10
compression
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!