A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Observer reproducibility of results from a low-dose 123I-metaiodobenzylguanidine cardiac imaging protocol in patients with heart failure. | LitMetric

Purpose: Imaging of the cardiac autonomic system with (123)I-metaiodobenzylguanidine (MIBG) is useful in the evaluation of patients with a variety of cardiac conditions, including heart failure (HF), but few data are available about the reproducibility of this technique. We assessed the observer reproducibility of the results from a low-dose (123)I-MIBG cardiac imaging protocol in patients with HF.

Methods: A total of 74 patients (62 men, age 67 ± 10 years) with HF and left ventricular systolic dysfunction (ejection fraction 31 ± 7 %) underwent low-dose (111 MBq) planar and single-photon emission computed tomography (SPECT) (123)I-MIBG cardiac sympathetic imaging. The intraclass coefficient of correlation (ICC), Lin's concordance correlation coefficient, and Bland-Altman analysis were used to evaluate the intraobserver and interobserver reproducibility of early and late heart-to-mediastinum (H/M) ratios and of defect scores on SPECT images. The κ statistic was used to evaluate the concordance rates for the identification of patients with a low H/M ratio (<1.60) on late planar imaging.

Results: The differences between measurements obtained twice by the same examiner and by two examiners were negligible for both early and late H/M ratios and for SPECT defect scores. These findings were confirmed by the results of Bland-Altman analysis, and ICC and Lin's coefficient values were excellent (>0.90) for all measurements. For the identification of patients with a low H/M ratio, the κ values were 0.90 for intraobserver concordance and 0.83 for interobserver concordance.

Conclusion: The present study showed a high observer reproducibility of planar H/M ratios and SPECT defect scores using a low-dose (123)I-MIBG cardiac imaging protocol in patients with HF.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-013-2461-4DOI Listing

Publication Analysis

Top Keywords

observer reproducibility
8
reproducibility low-dose
8
cardiac imaging
8
imaging protocol
8
protocol patients
8
heart failure
8
123i-mibg cardiac
8
cardiac
5
patients
5
low-dose 123i-metaiodobenzylguanidine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!