Background: Electric excitability in the ventricular wall is influenced by cellular electrophysiology and passive electric properties of the myocardium. Action potential (AP) rise time, an indicator of myocardial excitability, is influenced by conduction pattern and distance from the epicardial surface. This study examined AP rise times and conduction velocity as the depolarizing wavefront approaches the epicardial surface.

Methods And Results: Two-photon excitation of di-4-aminonaphthenyl-pyridinum-propylsulfonate was used to measure electric activity at discrete epicardial layers of isolated Langendorff-perfused rabbit hearts to a depth of 500 μm. Endo-to-epicardial wavefronts were studied during right atrial or ventricular endocardial pacing. Similar measurements were made with epi-to-endocardial, transverse, and longitudinal pacing protocols. Results were compared with data from a bidomain model of 3-dimensional (3D) electric propagation within ventricular myocardium. During right atrial and endocardial pacing, AP rise time (10%-90% of upstroke) decreased by ≈50% between 500 and 50 μm from the epicardial surface, whereas conduction velocity increased and AP duration was only slightly shorter (≈4%). These differences were not observed with other conduction patterns. The depth-dependent changes in rise time were larger at higher pacing rates. Modeling data qualitatively reproduced the behavior seen experimentally and demonstrated a parallel reduction in peak I(Na) and electrotonic load as the wavefront approaches the epicardial surface.

Conclusions: Decreased electrotonic load at the epicardial surface results in more rapid AP upstrokes and higher conduction velocities compared with the bulk myocardium. Combined effects of tissue depth and pacing rate on AP rise time reduce conduction safety and myocardial excitability within the ventricular wall.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.113.000334DOI Listing

Publication Analysis

Top Keywords

rise time
16
epicardial surface
12
action potential
8
rabbit hearts
8
excitability ventricular
8
ventricular wall
8
myocardial excitability
8
conduction velocity
8
wavefront approaches
8
approaches epicardial
8

Similar Publications

Advanced control strategy for AC microgrids: a hybrid ANN-based adaptive PI controller with droop control and virtual impedance technique.

Sci Rep

December 2024

Department of Theoretical Electrical Engineering and Diagnostics of Electrical Equipment, Institute of Electrodynamics, National Academy of Sciences of Ukraine, Beresteyskiy, 56, Kyiv-57, Kyiv, 03680, Ukraine.

In this paper, an improved voltage control strategy for microgrids (MG) is proposed, using an artificial neural network (ANN)-based adaptive proportional-integral (PI) controller combined with droop control and virtual impedance techniques (VIT). The control strategy is developed to improve voltage control, power sharing and total harmonic distortion (THD) reduction in the MG systems with renewable and distributed generation (DG) sources. The VIT is used to decouple active and reactive power, reduce negative power interactions between DG's and improve the robustness of the system under varying load and generation conditions.

View Article and Find Full Text PDF

Elevator fault diagnosis based on digital twin and PINNs-e-RGCN.

Sci Rep

December 2024

College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, 310018, China.

The rapid development of urbanization has led to a continuous rise in number of elevators. This has led to elevator failures from time to time. At present, although there are some studies on elevator fault diagnosis, they are more or less limited by the lack of data to make the research more superficial.

View Article and Find Full Text PDF

Civil structures are prone to dynamic loadings such as strong winds or ground excitations where torsion becomes an ongoing issue. This arises from a lack of coincidence of the center of mass (CM) and rigidity (CR), known as eccentricity. Seismic design codes often introduce two types of eccentricity: inherent (geometric) and accidental.

View Article and Find Full Text PDF

The Trapping Mechanism at the AlGaN/GaN Interface and the Turn-On Characteristics of the p-GaN Direct-Coupled FET Logic Inverters.

Nanomaterials (Basel)

December 2024

State Key Laboratory of ASIC and System, Shanghai Institute of Intelligent Electronics & Systems, School of Microelectronics, Fudan University, Shanghai 200433, China.

The trapping mechanism at the AlGaN/GaN interface in the p-GaN high electron mobility transistors (HEMTs) and its impact on the turn-on characteristics of direct-coupled FET logic (DCFL) inverters were investigated across various supply voltages () and test frequencies (). The frequency-conductance method identified two trap states at the AlGaN/GaN interface (trap activation energy - ranges from 0.345 eV to 0.

View Article and Find Full Text PDF

Exploring developmental changes in femoral midneck cross-sectional properties.

Anat Rec (Hoboken)

December 2024

Laboratorio de Evolución Humana, Universidad de Burgos, Edificio I+D+i/CIBA, Burgos, Spain.

This research delves deeper into previous works on femoral cross-sectional properties during ontogeny by focusing for the first time on the human femoral midneck. The ontogenetic pattern of cross-sectional properties at femoral midneck is established and compared with those at three different femoral locations: the proximal femur, the midshaft, and the distal femur. The study sample includes 99 femora (70 non-adults and 29 adults) belonging to archaeological specimens.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!