A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

How to measure cerebrospinal fluid pressure invasively and noninvasively. | LitMetric

How to measure cerebrospinal fluid pressure invasively and noninvasively.

J Glaucoma

Department of Otolaryngology, New York Eye and Ear Infirmary, New York, NY, USA.

Published: February 2014

We describe tympanic membrane displacement (TMD) testing for non-invasive estimation of intracranial pressure (ICP). With the TMD test, displacement of the tympanic membrane of the middle ear is recorded during elicitation of the acoustic middle-ear reflex (AR). Increased intracranial/perilymphatic pressure displaces the resting stapes footplate laterally so that TMD during the acoustic reflex is medial. Decreased intracranial/perilymphatic pressure displaces the baseline stapes footplate position medially (inward) so that TMD during the AR is lateral. The TMD typically is bidirectional when intracranial/perilymphatic pressure is normal. Discrepant findings have been reported for the sensitivity of the TMD test to ICP as the regression of TMD on invasive measurement of the ICP reveals substantial intersubject variability and overlap among patient and control groups. Large-sample research on TMD test performance in healthy persons and patients with various disorders affecting the ICP is needed using direct, invasive measures of the ICP as the gold standard. Research also is needed to examine whether non-invasive TMD testing can be used to investigate the trans-lamina cribrosa pressure difference in glaucoma.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0b013e3182934a6aDOI Listing

Publication Analysis

Top Keywords

tmd test
12
intracranial/perilymphatic pressure
12
tmd
9
tympanic membrane
8
tmd testing
8
pressure displaces
8
stapes footplate
8
pressure
6
icp
5
measure cerebrospinal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!