Catheter rupture after totally implantable access port (TIAP) implantation via the right internal jugular vein is thought to be very rare. We report a case of catheter rupture found 682 days after TIAP surgery in a 52-year-old woman with recurrent right breast cancer. It is possible that chronic stress at the flexure of the catheter induced by neck movements caused the catheter to rupture. Therefore, when inserting a TIAP via the right internal jugular vein, the site of venous puncture should be decided on carefully. Although a fracture of this type is rarely reported in the literature, the incidence of catheter injury of a TIAP inserted via the internal jugular vein at our institute is 1.8 %. This highlights the need to educate and caution medical staff and patients about preventing catheter fracture being caused by external factors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00595-013-0631-4 | DOI Listing |
J Neurointerv Surg
January 2025
Department of Neurosurgery, University at Buffalo Jacobs School of Medicine and Biomedical Sciences, Buffalo, New York, USA
Background: Early literature on the Woven EndoBridge (WEB) device reported 80-90% adequate aneurysm occlusion but low complete occlusion (40-55%). It is uncertain whether residual or recurrent aneurysms require re-treatment to prevent future rupture.
Objective: To systematically review the literature to meta-analyze occlusion and complication rates after re-treatment of these aneurysms.
Front Cardiovasc Med
January 2025
Department of Cardiology, University of Health Sciences, Erzurum Bolge Training and Research Hospital, Erzurum, Turkey.
Background: Our aim in this case was to remove the defective ventricular lead and the ruptured coronary sinus lead.
Methods: Entering through the right femoral vein and removing the coronary sinus lead with a pigtail catheter.
Results: In our attempt to extract the coronary sinus lead, it fractured.
Brain Sci
December 2024
Division of Neurointerventional Radiology, UMass-Chan Lahey Department of Radiology, Lahey Hospital and Medical Centre-Beth Israel Lahey Health, Burlington, MA 01805, USA.
Anterior choroidal artery (AChoA) aneurysms pose a challenge for both endovascular and clipping procedures. The eloquent territory supplied by the parent vessel has limited collateralization and its compromise can lead to significant morbidity. This study aims to analyze the clinical outcomes and procedure-related complications of clipping and endovascular treatment of AChoA aneurysms to aid physician decision making.
View Article and Find Full Text PDFJ Neurosurg Case Lessons
January 2025
Department of Neurological Surgery, Cooper University Health Care, Camden, New Jersey.
Background: External ventricular drains (EVDs) provide an invaluable diagnostic method for accessing cerebrospinal fluid and therapeutically treating elevated intracranial pressure. Although complications including hemorrhage and infection have been well documented, the formation of iatrogenic pseudoaneurysms following EVD placement has rarely been reported. The authors present a case of this exceedingly rare complication of iatrogenic pseudoaneurysm formation following EVD placement.
View Article and Find Full Text PDFBackground: Right ventricular pseudoaneurysms are extremely rare and there is no precise recommendation for their management.
Case Summary: We present the case of a successful coil embolization of a right ventricular pseudoaneurysm in a woman with chronic kidney disease due to perinuclear antineutrophil cytoplasmic antibody vasculitis and a history of difficult placement of a hemodialysis catheter.
Discussion: Ventricular pseudoaneurysm is a contained rupture of the ventricular wall that can occur due to several causes.