A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of acute endotoxemia on analog estimates of mean systemic pressure. | LitMetric

Effect of acute endotoxemia on analog estimates of mean systemic pressure.

J Crit Care

Cardiopulmonary Research Laboratory, Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA.

Published: October 2013

Dynamic estimates of mean systemic pressure based on a Guytonian analog model (Pmsa) appear accurate under baseline conditions but may not remain so during septic shock because blood volume distribution and resistances between arterial and venous beds may change. Thus, we examined the effect of acute endotoxemia on the ability of Pmsa, estimated from steady-state cardiac output, right atrial pressure, and mean arterial pressure, to reflect our previously validated instantaneous venous return measure of mean systemic pressure (Pmsi), derived from beat-to-beat measures of right ventricular stroke volume and right atrial pressure during positive pressure ventilation. We studied 6 splenectomized pentobarbital-anesthetized close chested dogs. Right ventricular stroke volume was measured by a pulmonary arterial electromagnetic flow probe. Instantaneous venous return measure of mean systemic pressure and Pmsa were calculated during volume loading and removal (±100-mL bolus increments×5) both before (control) and 30 minutes after endotoxin infusion (endo). Cardiac output increased (2628±905 vs 3560±539 mL/min; P<.05) and mean arterial pressure decreased (107±16 vs 56±12 mm Hg; P<.01) during endo. Changes in Pmsi and Pmsa correlated during both control and endo (r2=0.7) with minimal bias by Bland-Altman analysis (mean difference±95% confidence interval, 0.47±5.04 mm Hg). We conclude that changes in Pmsa accurately tracts Pmsi under both control and endo.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075759PMC
http://dx.doi.org/10.1016/j.jcrc.2013.04.007DOI Listing

Publication Analysis

Top Keywords

systemic pressure
16
acute endotoxemia
8
estimates systemic
8
pressure
8
cardiac output
8
atrial pressure
8
instantaneous venous
8
venous return
8
return measure
8
measure systemic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!