Although existing guidelines support the utilization of intracranial pressure (ICP) monitoring in patients with traumatic brain injury (TBI), the evidence suggesting benefit is limited. To evaluate the impact on outcome, we determined the relationship between ICP monitoring and mortality in centers participating in the American College of Surgeons Trauma Quality Improvement Program (TQIP). Data on 10,628 adults with severe TBI were derived from 155 TQIP centers over 2009-2011. Random-intercept multilevel modeling was used to evaluate the association between ICP monitoring and mortality after adjusting for important confounders. We evaluated this relationship at the patient level and at the institutional level. Overall mortality (n=3769) was 35%. Only 1874 (17.6%) patients underwent ICP monitoring, with a mortality of 32%. The adjusted odds ratio (OR) for mortality was 0.44 [95% confidence interval (CI), 0.31-0.63], when comparing patients with ICP monitoring to those without. It is plausible that patients receiving ICP monitoring were selected because of an anticipated favorable outcome. To overcome this limitation, we stratified hospitals into quartiles based on ICP monitoring utilization. Hospitals with higher rates of ICP monitoring use were associated with lower mortality: The adjusted OR of death was 0.52 (95% CI, 0.35-0.78) in the quartile of hospitals with highest use, compared to the lowest. ICP monitoring utilization rates explained only 9.9% of variation in mortality across centers. Results were comparable irrespective of the method of case-mix adjustment. In this observational study, ICP monitoring utilization was associated with lower mortality. However, variability in ICP monitoring rates contributed only modestly to variability in institutional mortality rates. Identifying other institutional practices that impact on mortality is an important area for future research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3796332 | PMC |
http://dx.doi.org/10.1089/neu.2012.2802 | DOI Listing |
Food Addit Contam Part B Surveill
January 2025
College of Agricultural Engineering Science, Food Science and Quality Control Department, University of Sulaimani, Sulaimani, Iraq.
Potential toxic elements are substances that can accumulate in foodstuffs and pose risks to human health even at low levels, or when their levels exceed safety thresholds. A total of 78 breakfast cereals were purchased from the Kurdistan region, Iraq. Their PTE levels were analysed and associated health risks were calculated.
View Article and Find Full Text PDFCurr Environ Health Rep
January 2025
School of Health Sciences, Purdue University, West-Lafayette, IN, 47906, USA.
Purpose Of Review: This review explores the use of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and X-ray Fluorescence (XRF) for quantifying metals and metalloids in biological matrices such as hair, nails, blood, bone, and tissue. It provides a comprehensive overview of these methodologies, detailing their technological limitations, application scopes, and practical considerations for selection in both laboratory and field settings. By examining traditional and novel aspects of each method, this review aims to guide researchers and clinical practitioners in choosing the most suitable analytical tool based on their specific needs for sensitivity, precision, speed, and sample preparation.
View Article and Find Full Text PDFNPJ Digit Med
January 2025
Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, GA, USA.
Noninvasive methods for intracranial pressure (ICP) monitoring have emerged, but none has successfully replaced invasive techniques. This observational study developed and tested a machine learning (ML) model to estimate ICP using waveforms from a cranial extensometer device (brain4care [B4C] System). The model explored multiple waveform parameters to optimize mean ICP estimation.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada.
Goal: Current methodologies for assessing cerebral compliance using pressure sensor technologies are prone to errors and issues with inter- and intra-observer consistency. RAP, a metric for measuring intracranial compensatory reserve (and therefore compliance), holds promise. It is derived using the moving correlation between intracranial pressure (ICP) and the pulse amplitude of ICP (AMP).
View Article and Find Full Text PDFMolecules
January 2025
Faculty of Chemistry, University of Warsaw, ul. Pasteura 1, 02-093 Warsaw, Poland.
Tellurium, recognized as one of the technology-critical elements, should be considered as a xenobiotic. Its application, i.a.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!