Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: The functional results and the complications following interlocking plate fixation of displaced proximal humerus fractures should be evaluated and compared with those following minimal invasive fixation techniques.
Patients And Methods: Fifty patients (30 women, 20 men, mean age 62.7 (18-91) years) were treated for a displaced proximal humerus fracture using an interlocking plate fixation (PHILOS®) between 2003 and 2004. The mean follow-up time was 12 (9-36) months. Functional and radiographic results (Constant-Murley and Neer scores) were analyzed and compared with an equivalent historical control group of 53 patients operated for the same fracture types using minimal invasive techniques (K-wires and/or cannulated screws) between 1995 and 1997. According to the OTA/AO classification, there were 15 type A, 18 type B, and 17 type C fractures in the plate fixation group, and 23, 25, and 5 of these types in the control group, respectively.
Results: The mean Neer score was 85.9, the mean Constant-Murley score 84, whereas 82.4 and 75.4 for the control group, respectively. Good and excellent results were seen in 78%, whereas in 70% in the control group. The results were dependent upon the fracture's type, sex, and patient's age. Complications were seen in 9 patients, whereas in 16 patients in the control group.
Interpretation: Using an interlocking plate, the indication of fixation of displaced proximal humerus fractures had been expanded to type C fractures. The implant failure rate can be reduced. The functional results achieved are better compared with those following minimal invasive techniques.