Sweeping as a multistep enrichment process in micellar electrokinetic chromatography: the retention factor gradient effect.

J Chromatogr A

University of Marburg, Department of Chemistry, Hans-Meerwein-Straße, D-35032 Marburg, Germany.

Published: July 2013

AI Article Synopsis

  • A new method for assessing sweeping efficiency in micellar electrokinetic chromatography (MEKC) has been developed, which considers variations in analyte conditions like distribution coefficient and electric conductivity.
  • The study focuses on p-hydroxybenzoates (parabens), benzamide, and aromatic amines, revealing that the enrichment factor is influenced not only by the sample zone retention factor but also by that in the background electrolyte (BGE), suggesting a more complex process than previously understood.
  • An additional factor, the retention factor gradient effect (RFGE), is introduced to explain the multistep nature of the sweeping process, with experimental validation confirming that high enrichment can be achieved by optimizing pH conditions to convert analytes into charged species compatible with

Article Abstract

The application of a new method developed for the assessment of sweeping efficiency in MEKC under homogeneous and inhomogeneous electric field conditions is extended to the general case, in which the distribution coefficient and the electric conductivity of the analyte in the sample zone and in the separation compartment are varied. As test analytes p-hydroxybenzoates (parabens), benzamide and some aromatic amines are studied under MEKC conditions with SDS as anionic surfactant. We show that in the general case - in contrast to the classical description - the obtainable enrichment factor is not only dependent on the retention factor of the analyte in the sample zone but also dependent on the retention factor in the background electrolyte (BGE). It is shown that in the general case sweeping is inherently a multistep focusing process. We describe an additional focusing/defocusing step (the retention factor gradient effect, RFGE) quantitatively by extending the classical equation employed for the description of the sweeping process with an additional focusing/defocusing factor. The validity of this equation is demonstrated experimentally (and theoretically) under variation of the organic solvent content (in the sample and/or the BGE), the type of organic solvent (in the sample and/or the BGE), the electric conductivity (in the sample), the pH (in the sample), and the concentration of surfactant (in the BGE). It is shown that very high enrichment factors can be obtained, if the pH in the sample zone makes possible to convert the analyte into a charged species that has a high distribution coefficient with respect to an oppositely charged micellar phase, while the pH in the BGE enables separation of the neutral species under moderate retention factor conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2013.04.069DOI Listing

Publication Analysis

Top Keywords

retention factor
20
general case
12
sample zone
12
factor gradient
8
distribution coefficient
8
electric conductivity
8
analyte sample
8
dependent retention
8
additional focusing/defocusing
8
organic solvent
8

Similar Publications

"I still can feel the sickness": Withdrawal experiences of people on methadone maintenance treatment.

J Subst Use Addict Treat

December 2024

Department of Social and Behavioral Sciences, School of Global Public Health, New York University, New York, NY 10003, USA; Center for Drug Use and HIV/HCV Research, School of Global Public Health, New York University, New York, NY 10003, USA.

Introduction: Opioid withdrawal is a regular occurrence for many people who use illicit opioids (PWUIO) involving acute physical and psychological pain. Yet, there is very little data on the withdrawal experience of people in methadone maintenance treatment (MMT) and almost none from the patients' experience. Learning more about patients' withdrawal experiences can help to inform policies and practices that are better suited to address withdrawal and may improve patient satisfaction as well as uptake and retention.

View Article and Find Full Text PDF

Background: Survival after transcatheter aortic valve replacement (TAVR) has markedly increased. Thus, other comorbidities will intersect patient trajectories and challenge follow-up.

Objectives: The aim of this study was to describe patient characteristics and hospitalizations at end of life to further improve the quality of life for patients undergoing TAVR.

View Article and Find Full Text PDF

Background: Longitudinal digital health studies combine passively collected information from digital devices, such as commercial wearable devices, and actively contributed data, such as surveys, from participants. Although the use of smartphones and access to the internet supports the development of these studies, challenges exist in collecting representative data due to low adherence and retention. We aimed to identify key factors related to adherence and retention in digital health studies and develop a methodology to identify factors that are associated with and might affect study participant engagement.

View Article and Find Full Text PDF

Precise Light-Driven Polarity of Stationary Phase for Regulating Gradient Separation of Liquid Chromatography.

Anal Chem

December 2024

Department of Chemistry, National Demonstration Centre for Experimental Chemistry Education, Yanbian University, Yanji City 133002, Jilin Province, China.

Generally, the traditional stationary phase for liquid chromatography is the key part, but with an in situ immutable property, leading to many separation limitations. Based on the former exploration of photosensitive gas chromatography, we successfully prepared a photosensitive monolithic capillary silica column with high light transmission, taking advantage of the reversible cis-trans isomerism of azobenzene. And the cis-trans isomerism has launched an effective, reversible, and precise control on the liquid chromatographic retention behavior just by photoinduction according to the theoretical basis of a good correlation between photoinduction time, -azobenzene ratio, and chromatographic retention factor () ( > 0.

View Article and Find Full Text PDF

Optimization of an analytical method based on the use of zwitterionic- phosphorylcholine -HILIC column for the determination of multiple polar emerging contaminants in reclaimed water.

J Chromatogr A

December 2024

Department of Chemical and Geological Sciences, University of Modena and Reggio Emilia, via Campi 103, 41125 Modena, Italy; LASIRE, University of Lille, Cité Scientifique, Villeneuve-d'Ascq, 59650, France.

The aim of this study was to optimize a Liquid Chromatography Mass Spectrometry (LC-MS) method using a zwitterionic phosphorylcholine HILIC column for the determination of several Persistent and Mobile Organic Contaminants (PMOC) in wastewater samples. An experimental design approach was implemented to both better understand the retention mechanisms of several polar compounds and to find the optimal operating conditions for their detection and quantification. Eleven PMOCs, with logD ranging from -5.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!