An Investigation of Three types of Tooth Implant Supported Fixed Prosthesis Designs with 3D Finite Element Analysis.

J Dent (Tehran)

Assisstant Professor, Department of Prosthodontics, Islamic Azad University of Medical Science, Branch of Dentistry, Tehran, Iran.

Published: January 2013

Objective: Tooth/implant supported fixed prostheses may present biomechanical design problems, as the implant is rigidly anchored within the alveolus, whereas the tooth is attached by the periodontal ligament to the bone allowing movement. Many clinicians prefer tooth/implant supported fixed prosthesis designs with rigid connectors. However, there are some doubts about the effect of attachment placement in different prosthesis designs. The purpose of this study was to examine the stresses accumulated around the implant and natural teeth under occlusal forces using three dimensional finite element analysis (3D FEA).

Materials And Methods: In this study, different connection designs of tooth/implant fixed prosthesis in distal extension situations were investigated by 3D FEA. Three models with various connection designs were studied; in the first model an implant rigidly connected to an abutment, in the second and third models an implant connected to abutment tooth with nonrigid connector in the distal part of the tooth and mesial part of the implant. In each model, a screw type implant (5×11mm) and a mandibular second premolar were used. The stress values of these models loaded with vertical forces (250N) were analyzed.

Results: There was no difference in stress distribution around the bone support of the implant. Maximum stress values were observed at the crestal bone of the implant. In all models, tooth movement was higher than implant movement.

Conclusion: There is no difference in using a rigid connector, non rigid connector in the distal surface of the tooth or in the mesial surface of an implant.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666065PMC

Publication Analysis

Top Keywords

supported fixed
12
fixed prosthesis
12
prosthesis designs
12
implant
11
finite element
8
element analysis
8
tooth/implant supported
8
implant rigidly
8
connection designs
8
connected abutment
8

Similar Publications

Background: Immune checkpoint inhibitors (ICIs) are recommended to treat patients with deficient mismatch repair/microsatellite instability high (dMMR/MSI-H) metastatic colorectal cancer (mCRC). Pivotal trials have fixed a maximum ICI duration of 2 years, without a compelling rationale. A shorter treatment duration has the potential to improve patients' quality of life and reduce both toxicity and cost without compromising efficacy.

View Article and Find Full Text PDF

In this study we have used a highly immersive virtual reality (VR) cycling environment where incongruence between virtual hill gradient (created by visual gradient and bike tilt angle) and actual workload (pedalling resistance) can experimentally manipulate perception of exercise effort. This therefore may provide a method to examine the role of effort perception in cardiorespiratory control during exercise. Twelve healthy untrained participants (7 men, age 26 ± 5 years) were studied during five visits.

View Article and Find Full Text PDF
Article Synopsis
  • This study focused on detecting Estrogen Receptor (ER), Progesterone Receptor (PR), and HER-2 in breast cancer to help categorize the disease and guide treatment choices.
  • Researchers compared two preservation methods for breast tissue samples: traditional formalin fixation and RNAlater, utilizing Immunohistochemistry (IHC) and Quantitative Polymerase Chain Reaction (qPCR) for analysis.
  • Findings revealed that ER and PR were positive in 60% of samples, while HER-2 was positive in only 25%, with no significant statistical difference between the results from the two preservation methods.
View Article and Find Full Text PDF

Background: The orexin/hypocretin neuropeptide system, primarily found in the lateral hypothalamus and perifornical region, modulates sleep, wakefulness, appetite, and cognitive function. One region with dense orexinergic projections is the basal forebrain (BF), which is the major source of acetylcholine in the neocortex and limbic structures such as the hippocampus. The basal forebrain cholinergic system mediates cognition and dysfunction is one of the key hallmarks of Alzheimer's disease.

View Article and Find Full Text PDF

Basic Science and Pathogenesis.

Alzheimers Dement

December 2024

University of Washington, Seattle, WA, USA.

Background: The BRAIN Initiative has stimulated development of novel single cell and spatial molecular approaches to understand human brain structure and function. However, traditional methods for human brain specimen collection, including retrospective archival tissues, have not been optimized for these latest methods. A modernized approach that optimizes tissue quality, anatomical precision, and comprehensive, quantitative neuropathological assessments is needed to maximize the impact of the tremendous investment and remarkable technological advances in human neuroscience research.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!