Objective: Jaundice is a common problem in neonatal period. Phototherapy is the most common treatment for neonatal jaundice. The purpose of this study was to determine the effect of adding white plastic cover around the phototherapy unit on hyperbilirubinemia in full term neonates with jaundice.

Methods: In this randomized controlled trial, over 12 months (October 2009 - September 2010), 182 term neonates with uncomplicated jaundice, admitted to neonatal unit of Imam Reza Hospital (AS) in Kermanshah province of Iran, were selected. They were randomized in two groups. Control group received conventional phototherapy without cover around the apparatus and covered group received conventional phototherapy with plastic cover around the unit. After enrolment, total serum bilirubin was measured every 12 hours. Phototherapy was continued until the total serum bilirubin decreased to or less than 12.5 mg/dl.

Findings: There were no significant differences between the two groups for gestational age, birth weight, postnatal age, weight (at admission), serum level of hemoglobin, hematocrit and reticulocyte count. Total serum bilirubin in covered group, during the first 48 hours of treatment, declined significantly than in control group (P. value=0.003). The cover around the phototherapy unit not only did not increase the side effects of phototherapy, but also had a positive impact in reducing duration of jaundice (P. value <0.0001) and duration of hospitalization (P. value <0.0001).

Conclusion: The study results showed that using white plastic cover around the phototherapy unit can increase the therapeutic effect of phototherapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3663303PMC

Publication Analysis

Top Keywords

plastic cover
12
cover phototherapy
12
phototherapy unit
12
term neonates
12
total serum
12
serum bilirubin
12
white plastic
8
phototherapy
8
unit hyperbilirubinemia
8
hyperbilirubinemia full
8

Similar Publications

Suspicion of vascular injury during endoscopic retrograde cholangiopancreatography (ERCP) should be raised in the event of intraprocedural bleeding, persistent hyperbilirubinemia, and sepsis despite biliary stenting. Most inadvertent portal vein (PV) cannulations during ERCP are innocuous, and mere withdrawal of guidewire and catheter suffices. However, unintentional PV stenting, particularly with larger metallic stents, increases the likelihood of significant bleeding.

View Article and Find Full Text PDF

Background: This investigation explores the potential impact of Negative Pressure Wound Therapy (NPWT) dressing on mommy makeover surgical wounds. The focus is on optimizing the healing process and post-surgical care to mitigate complications like wound dehiscence, seroma, and hematoma.

Patients And Methods: A prospective study spanned from October 2015 to April 2022, involving 40 patients undergoing mommy makeover surgery for aesthetic purposes.

View Article and Find Full Text PDF

Complex injuries to the posterior trunk can still pose a significant challenge to the reconstructive surgeon. Due to the lack of skin laxity, dependent anatomical location and the importance of the deeper structures, a systematic approach tailored to the individual defect should be considered for these types of reconstructions. In our case report, we present a reconstructive solution of a chronic defect of the back caused by resection of an ulceration.

View Article and Find Full Text PDF

Gender Gap? A Survey among Plastic Surgeons in Germany.

J Surg Educ

January 2025

Department of Plastic Surgery, University Hospital Muenster, Muenster, Germany; Department of Plastic and Reconstructive Surgery, Institute of Musculoskeletal Medicine, University of Muenster, Muenster, Germany; Department of Plastic, Reconstructive and Aesthetic Surgery, Hand Surgery, Fachklinik Hornheide, Muenster, Germany.

Introduction: There is an ongoing increase in the percentage of females in the field of Plastic Surgery in Germany. Currently, 29,1% of fellows and 46% of residents in Germany are female. Several studies have pointed out the various obstacles that female doctors, especially female plastic surgeons, are confronted with in their professional life.

View Article and Find Full Text PDF

Parametric finite element modeling of reinforced polymeric leaflets for improved durability.

J Mech Behav Biomed Mater

January 2025

School of Materials Science and Engineering, Colorado State University, 700 Meridian Ave, Fort Collins, 80523, CO, USA. Electronic address:

Hyaluronic acid-enhanced polyethylene polymeric TAVR shows excellent in vivo anti-calcific, anti-thrombotic, and in vitro hydrodynamic performance. However, during durability testing, impact wear and fatigue cause early valve failure. Heart valve durability can be improved by strengthening the leaflet with fiber reinforcement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!