Background And Purpose: The hypothesis that MS could be provoked by a derangement of the blood outflow from the brain has been largely discredited. In part, it was because data on the normal pattern of outflow are scarce and obtained with different methods. The aim of this study was to evaluate the normal pattern of outflow for the vertebral and internal jugular veins in healthy subjects with multigate color Doppler.
Materials And Methods: Twenty-five volunteers were studied to assess vessel area, mean velocity, and flow for the vertebral and internal jugular veins in the supine and sitting positions.
Results: In the sitting position, flow decreases, both in vertebral veins and internal jugular veins, as the total vessel area decreases (from 0.46 ± 0.57 to 0.09 ± 0.08 cm(2)), even if the mean velocity increases (from 12.58 ± 10.19 to 24.14 ± 17.60 cm/s). Contrary to what happens to the blood inflow, outflow in the supine position, through vertebral and internal jugular veins, is more than twice the outflow in the sitting position (739.80 ± 326.32 versus 278.24 ± 207.94 mL/min). In the sitting position, on application of very low pressure to the skin with the sonography probe, internal jugular veins rarely appear to occlude. A pronounced difference of diameter between internal jugular veins was present in approximately one-third of subjects.
Conclusions: Our results support the view that other outflow pathways, like the vertebral plexus, play a major role in the normal physiology of brain circulation and must be assessed to obtain a complete picture of blood outflow.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7965434 | PMC |
http://dx.doi.org/10.3174/ajnr.A3557 | DOI Listing |
J Clin Med
January 2025
Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, Moscow 107031, Russia.
Ultrasonographic assessment of the diameters of various veins and their indices are among the most applied diagnostic tools for evaluating fluid responsiveness in clinical practice. Despite their widespread use, there is no definitive answer on which is preferable. Our study aimed to investigate the diagnostic accuracy of different venous diameters and their indices to assess fluid responsiveness.
View Article and Find Full Text PDFBiomedicines
January 2025
Department of Medicine and Clinical Science, Graduate School of Medicine, Yamaguchi University, Ube 755-8505, Japan.
: Hydrogen gas (H) has been shown to be effective in the treatment of various clinical conditions, from acute illnesses to chronic illnesses. However, its clinical indications and the corresponding appropriate hydrogen delivery methods have yet to be determined. This is due to the fact that the pharmacokinetics and pharmacodynamics of hydrogen in each delivery method have not been experimentally proven.
View Article and Find Full Text PDFBioengineering (Basel)
January 2025
School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, Brisbane, QLD 4072, Australia.
The haptic fidelity of biomimetic materials used in the design of procedural task trainers is of growing interest to the medical community. Shore hardness has been proposed as a method for assessing tissue biomechanics and replicating the results as a way to increase the fidelity of biomimetics to tissues. However, there is limited research on the reliability of human tissue measurements using Shore scales.
View Article and Find Full Text PDFAnn Card Anaesth
January 2025
Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
Ann Card Anaesth
January 2025
Department of Onco-Anesthesiology and Palliative Medicine, DRBRAIRCH, AIIMS, New Delhi, India.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!