Introduction: The aims of our study were to evaluate the effect of application of Adaptive Statistical Iterative Reconstruction (ASIR) algorithm on the radiation dose of coronary computed tomography angiography (CCTA) and its effects on image quality of CCTA and to evaluate the effects of various patient and CT scanning factors on the radiation dose of CCTA.
Methods: This was a retrospective study that included 347 consecutive patients who underwent CCTA at a tertiary university teaching hospital between 1 July 2009 and 20 September 2011. Analysis was performed comparing patient demographics, scan characteristics, radiation dose and image quality in two groups of patients in whom conventional Filtered Back Projection (FBP) or ASIR was used for image reconstruction.
Results: There were 238 patients in the FBP group and 109 patients in the ASIR group. There was no difference between the groups in the use of prospective gating, scan length or tube voltage. In ASIR group, significantly lower tube current was used compared with FBP group, 550 mA (450-600) vs. 650 mA (500-711.25) (median (interquartile range)), respectively, P < 0.001. There was 27% effective radiation dose reduction in the ASIR group compared with FBP group, 4.29 mSv (2.84-6.02) vs. 5.84 mSv (3.88-8.39) (median (interquartile range)), respectively, P < 0.001. Although ASIR was associated with increased image noise compared with FBP (39.93 ± 10.22 vs. 37.63 ± 18.79 (mean ± standard deviation), respectively, P < 0.001), it did not affect the signal intensity, signal-to-noise ratio, contrast-to-noise ratio or the diagnostic quality of CCTA.
Conclusion: Application of ASIR reduces the radiation dose of CCTA without affecting the image quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1754-9485.12019 | DOI Listing |
Herz
January 2025
Faculty of Medicine, Department of Cardiology, Bilecik Şeyh Edebali University, Pelitözü Mahallesi Fatih Sultan Mehmet Blv. No. 27 Merkez, Bilecik, Turkey.
Background: The aim of this study was to compare the efficacy outcomes of the traditional Judkins left and right catheters with those of the recently introduced Tiger catheter in female participants aged 65 years and older who underwent transradial coronary angiography.
Methods: A cohort of 160 female patients aged 65 and older who were scheduled for coronary angiography (CAG) were divided into two groups according to the use of Tiger (n = 80) or Judkins (n = 80) catheters for radial angiography at a ratio of 1:1, respectively. We analyzed the effectiveness of the Tiger and Judkins catheters, the incidence of catheter failure, contrast volume, CAG time, fluoroscopy time, dose-area product (in mGy/cm), and the occurrence of radial spasm.
J Nucl Med
January 2025
Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland; and.
The treatment regimen for [Lu]Lu-prostate-specific membrane antigen (PSMA) 617 therapy follows that of chemotherapy: 6 administrations of a fixed activity, each separated by 6 wk. Mathematic modeling can be used to test the hypothesis that the current treatment regimen for a radiopharmaceutical modality is suboptimal. A mathematic model was developed to describe tumor growth during [Lu]Lu-PSMA therapy.
View Article and Find Full Text PDFEcotoxicol Environ Saf
January 2025
NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, Jilin 130021, PR China. Electronic address:
Exposure of PM2.5 can cause different degrees of lung injury, which is referred with inflammatory response. Some evidences showed that low-dose radiation (LDR) induces hormesis in immune, however, it is unknown if LDR ameliorates the PM2.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Department of Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, GERMANY.
Orthotopic tumor models in pre-clinical translational research are becoming increasingly popular, raising the demands on accurate tumor localization prior to irradiation. This task remains challenging both in X-ray and proton computed tomography (xCT and pCT, respectively), due to the limited contrast of tumor tissue compared to the surrounding tissue. We investigate the feasibility of gadolinium oxide nanoparticles as multimodal contrast enhancement agent for both imaging modalities.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Department of Accelerator and Medical Physics, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, JAPAN.
The tumor microenvironment characterized by heterogeneously organized vasculatures causes intra-tumoral heterogeneity of oxygen partial pressure at the cellular level, which cannot be measured by current imaging techniques. The intra-tumoral cellular heterogeneity may lead to a reduction of therapeutic effects of radiation. The purpose of this study was to investigate the effects of the heterogeneity on biological effectiveness of H-, He-, C-, O-, and Ne-ion beams for different oxygenation levels, prescribed dose levels, and cell types.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!