Purpose: To accelerate data acquisition by undersampling phase encoding (PE) lines in MR imaging, an aliasing separation method by applying additional encoding gradients which result in voxel shape modification is proposed.
Methods: An imaging technique which achieves two directional accelerations by undersampling both PE lines in 3D imaging with aliasing separation gradients is proposed. A simple and fast reconstruction process using shift correction or gridding is followed. Phantom and in vivo experiments are performed to show the characteristics and acceleration capability of the proposed method. Further acceleration is achieved by combining with parallel acquisition techniques.
Results: The proposed technique shows anisotropic resolution pattern due to voxel shearing which increases proportionally with the acceleration factor. This characteristic is analyzed in both image domain and k-space and is illustrated by grid phantom imaging results. In in vivo experiment, 3D imaging results are presented with 6× acceleration using the proposed technique and ∼12× acceleration combining with parallel imaging technique.
Conclusions: By applying separation gradients along both PE directions in 3D MR imaging, aliasing artifacts have been successfully separated and a high acceleration is achieved for whole brain 3D MR imaging with slight blurring due to voxel shearing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.4803501 | DOI Listing |
J Exp Biol
January 2025
Independent researcher, 74 Eccleston Square, London, UK.
The function of zebra stripes has long puzzled biologists: contrasted and conspicuous colours are unusual in mammals. The puzzle appears solved: two lines of evidence indicate that they evolved as a protection against biting flies, the geographical coincidence of stripes and exposure to trypanosomiasis in Africa and field experiments showing flies struggling to navigate near zebras. A logical mechanistic explanation would be that stripes interfere with flies' analysis of the optic flow; however, both spatio-temporal aliasing and the aperture effect seem ruled out following recent experiments showing that randomly checked patterns also interfere with flies' capacity to navigate near zebras.
View Article and Find Full Text PDFbioRxiv
December 2024
Lyda Hill Department of Bioinformatics, UT Southwestern Medical Center, Dallas, TX 75390, USA.
Oblique plane microcopy (OPM), a variant of light-sheet fluorescence microscopy (LSFM), enables rapid volumetric imaging without mechanically scanning the sample or an objective. In an OPM, the sample space is mapped to a distortion free image space via remote focusing, and the oblique light-sheet plane is mapped via a tilted tertiary imaging system onto a camera. As a result, the 3D point-spread function and optical transfer function are tilted to the optical axis of the tertiary imaging system.
View Article and Find Full Text PDFCardiovasc Eng Technol
January 2025
Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification method. However, it is known for its tendency to underestimate MR and its dependence on user expertise.
View Article and Find Full Text PDFEur J Radiol Open
June 2025
Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Background: Deep learning (DL) accelerated controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE), provides high spatial resolution T1-weighted imaging of the upper abdomen. We aimed to investigate whether DL-CAIPIRINHA-VIBE can improve image quality, vessel conspicuity, and lesion detectability compared to a standard CAIPIRINHA-VIBE in renal imaging at 3 Tesla.
Methods: In this prospective study, 50 patients with 23 solid and 45 cystic renal lesions underwent MRI with clinical MR sequences, including standard CAIPIRINHA-VIBE and DL-CAIPIRINHA-VIBE sequences in the nephrographic phase at 3 Tesla.
Radiographics
January 2025
From the Department of Radiology, Cardiovascular Imaging, Mayo Clinic, 200 1st St SW, Rochester, MN 559905 (P.S.R., P.A.A.); Department of Radiology, Division of Cardiothoracic Imaging, Jefferson University Hospitals, Philadelphia, Pa (B.S.); Department of Radiology, Baylor Health System, Dallas, Tex (P.R.); Department of Diagnostic Radiology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR (M.Y.N.); and Department of Diagnostic Radiology, Cleveland Clinic, Cleveland, Ohio (M.A.B.).
Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!