Evaluation of a multiplex assay for estimation of HIV-1 incidence.

PLoS One

Division of HIV/AIDS Prevention, National Center for HIV/AIDS, Hepatitis, STD, and TB Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, United States of America.

Published: January 2014

Objectives: Accurate methods of estimating HIV-1 incidence are critical for monitoring the status of the epidemic and the impact of prevention strategies. Although several laboratory-based tests have been developed strictly for this purpose, several limitations exist and improved methods or technologies are needed. We sought to further optimize a previously described bead-based, HIV-1-specific multiplex assay with the capability of measuring multiple immune responses for determining recent infection.

Methods: We refined the customized HIV-1 Bio-Plex assay by determining cutoffs and mean durations of recency (MDR), based on the reactivity to longitudinal seroconversion specimens (n = 1347) from 311 ART-naïve, HIV-1-infected subjects. False-recent rates (FRRs) were calculated for various long-term cohorts, including AIDS patients, individuals on ART, and subtype C specimens. Incidence was estimated for each individual assay analyte from a simulated population with a known incidence of 1%. For improved incidence estimates, multi-analyte algorithms based on combinations of 3 to 6 analytes were evaluated and compared to the performance of each individual analyte.

Results: The MDR for the six analytes varied from 164.2 to 279.4 days, while the multi-analyte algorithm MDRs were less variable with a minimum and maximum value of 228.4 and 277.9 days, respectively. The FRRs for the 7 multi-analyte algorithms evaluated in this study varied from 0.3% to 3.1%, in a population of ART-naïve, long-term individuals. All algorithms yielded improved incidence estimates as compared to the individual analytes, predicting an incidence of 0.95% to 1.02%.

Conclusions: The HIV-specific multiplex assay described here measures several distinct immune responses in a single assay, allowing for the consideration of multi-analyte algorithms for improved HIV incidence estimates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3661489PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0064201PLOS

Publication Analysis

Top Keywords

multiplex assay
12
incidence estimates
12
multi-analyte algorithms
12
incidence
8
hiv-1 incidence
8
immune responses
8
improved incidence
8
assay
6
evaluation multiplex
4
assay estimation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!