A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Wideband monaural envelope correlation perception. | LitMetric

Wideband monaural envelope correlation perception.

Adv Exp Med Biol

Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA.

Published: November 2013

This study investigated monaural envelope correlation perception (Richards 1987) for noise bandwidths ranging from 25 to 1,600 Hz. The high-frequency side of the low band was fixed at 3,000 Hz and the low-frequency side of the high band was fixed at 3,500 Hz. When comodulated, the magnitude spectra of the pair of noise bands were either identical or reflected around the midpoint. Six listeners with normal hearing participated. Listeners showed similar performance for identical and reflected-spectrum conditions, with best performance usually occurring for bandwidths between 200 and 800 Hz. Results were considered in terms of envelope comparisons of waveforms at the outputs of multiple peripheral filters or envelope comparisons of waveforms at the outputs of central filters set to the bandwidths of the noise stimuli. Some aspects of the results were incompatible with the account based on multiple peripheral filters. However, the results of a supplementary condition involving the gating of band subregions indicated that this incompatibility could be accounted for by nonoptimal weighting of peripheral filter outputs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4607272PMC
http://dx.doi.org/10.1007/978-1-4614-1590-9_42DOI Listing

Publication Analysis

Top Keywords

monaural envelope
8
envelope correlation
8
correlation perception
8
band fixed
8
envelope comparisons
8
comparisons waveforms
8
waveforms outputs
8
multiple peripheral
8
peripheral filters
8
wideband monaural
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!