Sixty-seven patients referred to a sleep laboratory with a tentative diagnosis of obstructive sleep apnea were examined with a device designed for home use as an apnea screening system. Direct comparison was made between data obtained by the portable device and by data acquired simultaneously with standard polysomnographic techniques. The portable recorder measured nasal/oral airflow, chest wall movement, cardiac rhythm, and blood oxygen saturation. There was no significant difference in the number of disordered breathing events (apneas and hypopneas) recorded by the two systems. The portable device was found to have a sensitivity of 95% and a specificity of 96%. Indications and limitations for use of the portable home apnea screening test are reviewed and guidelines for normalcy suggested.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00007611-199007000-00006DOI Listing

Publication Analysis

Top Keywords

sleep apnea
12
apnea screening
12
portable device
8
apnea
5
portable
5
verification sleep
4
apnea portable
4
portable sleep
4
device
4
screening device
4

Similar Publications

Aim: Sleep apnoea syndrome (SAS) is a common sleep disorder associated with heightened cardiovascular risks, yet sex-specific differences in these risks remain unclear.

Methods: This retrospective observational cohort study utilized the JMDC Claims Database, covering >5 million individuals in Japan. We analyzed data from 4,173,702 individuals (2,406,930 men, 1,766,772 women) after excluding those with central SAS, cardiovascular disease, and incomplete lifestyle questionnaire data.

View Article and Find Full Text PDF

Aim: The current study aimed to assess the oropharyngeal space using cone-beam computed tomography (CBCT) and its effect on airway volume both before and after denture placement.

Materials And Methods: For this investigation, a total of 15 individuals with fully edentulous upper and lower ridges, ranging in age from 40 to 70, were taken into consideration. A recording of the pulmonary function test was made both prior to and following full denture recovery.

View Article and Find Full Text PDF

Objectives: We aimed to characterize a craniofacial skeletal phenotype (CSP) of adult obstructive sleep apnea (OSA) patients from a multidimensional perspective, exploring the impact of transverse skeletal discrepancy (TSD) on multivariable polysomnographic profiles.

Materials And Methods: This retrospective, cross-sectional study included 102 adult OSA patients. Sagittal, vertical, and transverse skeletal patterns were categorized on the cone beam computed tomography images.

View Article and Find Full Text PDF

Objective: Common examinations for diagnosing obstructive sleep apnea (OSA) are polysomnography (PSG) and home sleep apnea testing (HSAT). However, both PSG and HSAT require that sensors be attached to a subject, which may disturb their sleep and affect the results. Hence, in this study, we aimed to verify a wireless radar framework combined with deep learning techniques to screen for the risk of OSA in home-based environments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!