Objective: The aim of this study was to develop a user-friendly way of measuring patients' threshold and supra-threshold hearing, with potential for application in clinical research. The end-product of these tests is a graphical profile summarizing absolute threshold, frequency selectivity, and compression characteristics across a spectrum of frequencies (0.25-6 kHz).
Design: A battery of three psychophysical hearing tests consisted of measures of absolute threshold, frequency selectivity, and compression. An automated, cued, single-interval, adaptive tracking procedure was employed. The tests results were collated and used to generate a readily visualized 'profile' for each listener.
Study Sample: Participants were 83 adults (57 impaired-hearing and 26 good-hearing, age 20-75 years).
Results: Listeners tolerated the tests well. Single-ear profiles were obtained in an average of 74 minutes testing time (range 46-120 minutes). The variability of individual measurements was low. Substantial differences between normal and impaired listeners and also among the impaired listeners were observed. Qualitative differences in compression and frequency-selectivity were seen that could not be predicted by threshold measurements alone.
Conclusions: The hearing profiles are informative with respect to supra-threshold hearing performance and the information is easily accessible through the graphical display. Further development is required for routine use in a clinical context.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/14992027.2013.796530 | DOI Listing |
eNeuro
January 2025
Hearing Technology @ WAVES, Department of Information Technology, Ghent University, Technologiepark 216, 9052 Zwijnaarde, Belgium
Speech intelligibility declines with age and sensorineural hearing damage (SNHL). However, it remains unclear whether cochlear synaptopathy (CS), a recently discovered form of SNHL, significantly contributes to this issue. CS refers to damaged auditory-nerve synapses that innervate the inner hair cells and there is currently no go-to diagnostic test available.
View Article and Find Full Text PDFInt J Audiol
December 2024
Medizinische Physik and Cluster of Excellence Hearing4all, Universität Oldenburg, Oldenburg, Germany.
Objective: The benefit of using smartphones for hearing tests in a non-supervised, rapid, and contactless way has drawn a lot of interest, especially if supra-threshold measures are assessed that go beyond audiogram-based measures alone. It is unclear, nevertheless, how well these measures compare to more supervised and regulated manual audiometric assessments. The aim of this study is to validate such smartphone-based methods against standardised laboratory assessments.
View Article and Find Full Text PDFHear Res
November 2024
Interacoustics Research Unit, Ørsteds Plads, Building 352, 2800 Kgs. Lyngby, Denmark.
Over the last decade, multiple studies have shown that hearing-impaired listeners' speech-in-noise reception ability, measured with audibility compensation, is closely associated with performance in spectro-temporal modulation (STM) detection tests. STM tests thus have the potential to provide highly relevant beyond-the-audiogram information in the clinic, but the available STM tests have not been optimized for clinical use in terms of test duration, required equipment, and procedural standardization. The present study introduces a quick-and-simple clinically viable STM test, named the Audible Contrast Threshold (ACT™) test.
View Article and Find Full Text PDFJ Clin Med
July 2024
Cochlear Deutschland, 30539 Hannover, Germany.
In cochlear implant (CI) treatment, there is a large variability in outcome. The aim of our study was to identify the independent audiometric measures that are most directly relevant for describing this variability in outcome characteristics of CI recipients. An extended audiometric test battery was used with selected adult patients in order to characterize the full range of CI outcomes.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
September 2024
Department of Otorhinolaryngology, Head and Neck Surgery, Otto Körner, Rostock University Medical Center, Doberaner Strasse 137-139, 18057, Rostock, Germany.
Purpose: Patients with age-related hearing loss complain often about reduced speech perception in adverse listening environment. Studies on animals have suggested that cochlear synaptopathy may be one of the primary mechanisms responsible for this phenomenon. A decreased wave I amplitude in supra-threshold auditory brainstem response (ABR) can diagnose this pathology non-invasively.