A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Field of view comparison between two-dimensional and three-dimensional endoscopy. | LitMetric

Objectives/hypothesis: Relative to microscopic transnasal surgery, endoscopic surgery provides improved visualization with an increased field of view. Advances such as high-definition (HD) and three-dimensional (3D) endoscopy have been introduced and clearly improve visualization. However, do both technologies maintain an increased field of view? We hypothesize that the field of view of 3D endoscopy is restricted relative to two-dimensional (2D) HD endoscopy.

Study Design: Laboratory investigation, prospective case series.

Methods: Standard measurements at 6-cm and 2-cm working distances where made to determine the comparative field of view utilizing Storz 0° 2D HD and Visionsense 3D endoscopes. Relative measurements were then made to determine field of view. Five clinical patients were then utilized to confirm laboratory studies and demonstrate the relative field of view change.

Results: 3D endoscopy demonstrates a 52% loss of field of view compared to 2D endoscopy in a controlled lab testing. This was confirmed in a small clinical patient series where a 55% ± 3% relative field of view reduction was observed.

Conclusions: When working with 3D endoscopy in a currently available commercial product, the operator should be aware that relative to HD 2D endoscopy, there is a field of view restriction of 52%.

Level Of Evidence: N/A.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lary.24222DOI Listing

Publication Analysis

Top Keywords

field view
36
field
10
three-dimensional endoscopy
8
increased field
8
view
8
relative field
8
endoscopy
7
relative
6
view comparison
4
comparison two-dimensional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!