Fractures of the anatomical neck of the scapula: two cases and review of the literature.

Arch Orthop Trauma Surg

Department of Orthopaedic Trauma, First Faculty of Medicine, Central Military Hospital, Charles University, U Vojenské nemocnice 1200, 169 02, Prague 6, Czech Republic.

Published: August 2013

Anatomical neck fractures of the scapula are rare. The authors have found in the literature only four radiologically documented fractures of the anatomical neck of the scapula. Two of them were published by Hardegger et al., the third case was published by Arts and Louette. The last case, in fact only a radiograph and a rather poor 3D CT reconstruction of a fracture of the anatomical neck of scapula, was published by Jeong and Zuckerman. Together with author's two patients, the group of radiologically verified anatomical neck fractures of the scapula comprises six cases in total (four men, one woman, one gender unspecified). Analysis of the radiographs showed that in all these cases, the fracture line separated only the glenoid fossa from the scapular body, with a short spike of the lateral border of the scapula. The proximal part of the vertical fracture line ran into the coracoglenoid notch, between the upper border of the glenoid and the base of the coracoid process. The distal part of the fracture line crossed the lateral border of the scapular body 2-4 cm distal to the inferior pole of the glenoid fossa. The gleniod fragment was always formed by the glenoid fossa and a short spike of the lateral border of the scapular body. In five cases, the glenoid fragment, together with the humeral head, was displaced distally and the humeral head came to lie below the level of the coracoid process. At the same time, the glenoid fragment rotated into a valgus position. Only in one case, did the radiographs fail to show valgus displacement and the fracture was angulated in the transverse plane. In all six cases, the subacromial space between the acromion and the humeral head was widened. All fractures were operated on via a Judet posterior approach. In five cases, the outcome of the operation was assessed at 3, 5, 12, 21 and 120 months after surgery, three-being rated as excellent or very good, one as good and one as poor.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-013-1783-9DOI Listing

Publication Analysis

Top Keywords

anatomical neck
20
neck scapula
12
glenoid fossa
12
scapular body
12
lateral border
12
humeral head
12
fractures anatomical
8
neck fractures
8
fractures scapula
8
scapula published
8

Similar Publications

Purpose: To describe a case of short common trunk of the occipital artery (OA) and ascending pharyngeal artery (APA) arising from the internal carotid artery (ICA).

Methods: A 36-year-old woman with a history of surgical resection of a right lateral ventricular meningioma and atheromatous plaque of the right ICA underwent cranial magnetic resonance (MR) imaging and MR angiography of the head and neck region with a 3-Tesla scanner.

Results: MR angiography of the neck region showed a small atheromatous plaque at the origin of the right ICA and an anomalous artery arising from the posteromedial aspect of the right ICA at the distal end of the carotid bulb.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Revisiting Visual Criteria of the Ideal Neck in the Young Caucasian Female.

Aesthet Surg J

January 2025

Plastic surgeon in private practice, Dallas, TX, USA.

Background: The description of the aesthetically ideal neck was first described by Ellenbogen and colleagues in 1980. Since then, visual and aesthetic goals of patients have evolved as new surgical techniques have been described.

Objectives: Our study aims to provide current objective data regarding the aesthetically ideal neck in a young Caucasian female and evaluate Ellenbogen's original criteria for a youthful neck in this specific population.

View Article and Find Full Text PDF

Hypothesis: Proximal humerus fractures present a treatment challenge due to varied fracture configurations and a lack of consensus on optimal management. Locking plate designs offer promising solutions, yet technical guidelines for successful outcomes remain elusive. Complications are common, with fixation-related failures often attributed to varus collapse.

View Article and Find Full Text PDF

This case report presents an atypical transverse cervical artery with its detailed anatomy, morphogenesis, and association with the high arch-shaped subclavian artery. The atypical arteries, related arteries, and adjacent cervical and brachial plexuses were macroscopically examined in a 98-year-old Japanese female cadaver donated to The Nippon Dental University for medical education and research. The atypical deep branch of the transverse cervical artery originated from the internal thoracic artery and passed through between the C5 and C6 roots, in close contact with the C5 and C6 junction, to reach the dorsal side of the brachial plexus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!