Purpose. To compare the autofluorescence images of the Zeiss versus Topcon eye fundus cameras and design an objective way to quantify it. Procedures. The IMAGEJ software was used to determine the gray level corresponding to the darkest veins and the peripapillary ring (thresholds), the level of white of the brightest perifoveal area, their difference (contrast level), and the suprathreshold area for each photograph. Results. Carl Zeiss has higher contrast values than Topcon. The Topcon contrast presented a crest with further decline as the suprathreshold area continued to increase. On the contrary, the Zeiss profile did not decline in contrast. Conclusions and Message. The Carl Zeiss camera showed superior contrast ability over the Topcon when performing autofluorescence imaging. We set objective parameters to compare fundus cameras FAF images. These parameters could be the base to objectively measure and determine changes and realize followup to areas of hyper- or hypofluorescence.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3655590 | PMC |
http://dx.doi.org/10.1155/2013/309192 | DOI Listing |
Sensors (Basel)
December 2024
Institute of Smart Systems and Services, Pforzheim University, 75175 Pforzheim, Germany.
Multispectral imaging (MSI) enables non-invasive tissue differentiation based on spectral characteristics and has shown great potential as a tool for surgical guidance. However, adapting MSI to open surgeries is challenging. Systems that rely on light sources present in the operating room experience limitations due to frequent lighting changes, which distort the spectral data and require countermeasures such as disruptive recalibrations.
View Article and Find Full Text PDFStrahlenther Onkol
January 2025
Department of Radiation Oncology, University Hospital Düsseldorf, Düsseldorf, Germany.
Purpose: The aim of this review is to give an overview of the results of prospective and retrospective studies using allogenic reconstruction and postmastectomy radiotherapy (PMRT) in breast cancer and to make recommendations regarding this interdisciplinary approach.
Materials And Methods: A PubMed search was conducted to extract relevant articles from 2000 to 2024. The search was performed using the following terms: (breast cancer) AND (reconstruction OR implant OR expander) AND (radiotherapy OR radiation).
Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).
Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye.
J Refract Surg
January 2025
Purpose: To apply a new method, the Taylor Diagram, and a new concept, the centered root mean square error (cRMSE), in evaluating the performance of IOL formulas.
Methods: The preoperative biometrics were measured with the IOLMaster 700 (Carl Zeiss Meditec) and the postoperative spherical equivalent refraction (SER) was calculated in 888 anonymous patients. The Taylor Diagram was applied to visualize the centered root mean square error (cRMSE) and the correlation coefficient between the predictions and the observations (R).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!