Purpose: This study evaluated the effect of different surface conditioning protocols on the repair strength of resin composite to the zirconia core / veneering ceramic complex, simulating the clinical chipping phenomenon.

Materials And Methods: Forty disk-shaped zirconia core (Lava Zirconia, 3M ESPE) (diameter: 3 mm) specimens were veneered circumferentially with a feldspathic veneering ceramic (VM7, Vita Zahnfabrik) (thickness: 2 mm) using a split metal mold. They were then embedded in autopolymerizing acrylic with the bonding surfaces exposed. Specimens were randomly assigned to one of the following surface conditioning protocols (n = 10 per group): group 1, veneer: 4% hydrofluoric acid (HF) (Porcelain Etch) + core: aluminum trioxide (50-µm Al2O3) + core + veneer: silane (ESPE-Sil); group 2: core: Al2O3 (50 µm) + veneer: HF + core + veneer: silane; group 3: veneer: HF + core: 30 µm aluminum trioxide particles coated with silica (30 µm SiO2) + core + veneer: silane; group 4: core: 30 µm SiO2 + veneer: HF + core + veneer: silane. Core and veneer ceramic were conditioned individually but no attempt was made to avoid cross contamination of conditioning, simulating the clinical intraoral repair situation. Adhesive resin (VisioBond) was applied to both the core and the veneer ceramic, and resin composite (Quadrant Posterior) was bonded onto both substrates using polyethylene molds and photopolymerized. After thermocycling (6000 cycles, 5°C-55°C), the specimens were subjected to shear bond testing using a universal testing machine (1 mm/min). Failure modes were identified using an optical microscope, and scanning electron microscope images were obtained. Bond strength data (MPa) were analyzed statistically using the non-parametric Kruskal-Wallis test followed by the Wilcoxon rank-sum test and the Bonferroni Holm correction (α = 0.05).

Results: Group 3 demonstrated significantly higher values (MPa) (8.6 ± 2.7) than those of the other groups (3.2 ± 3.1, 3.2 ± 3, and 3.1 ± 3.5 for groups 1, 2, and 4, respectively) (p < 0.001). All groups showed exclusively adhesive failure between the repair resin and the core zirconia. The incidence of cohesive failure in the ceramic was highest in group 3 (8 out of 10) compared to the other groups (0/10, 2/10, and 2/10, in groups 1, 2, and 4, respectively). SEM images showed that air abrasion on the zirconia core only also impinged on the veneering ceramic where the etching pattern was affected.

Conclusion: Etching the veneer ceramic with HF gel and silica coating of the zirconia core followed by silanization of both substrates could be advised for the repair of the zirconia core / veneering ceramic complex.

Download full-text PDF

Source
http://dx.doi.org/10.3290/j.jad.a29717DOI Listing

Publication Analysis

Top Keywords

zirconia core
24
core veneer
24
veneering ceramic
20
core
17
veneer silane
16
surface conditioning
12
resin composite
12
core veneering
12
ceramic complex
12
veneer core
12

Similar Publications

: This study aimed to investigate the fracture strength of a novel-designed Zirconia crown before and after access opening, and to evaluate the mode of fracture and the time needed for initial penetration through the crown. : This study involved the design and testing of 60 zirconia crowns, divided into three groups (20 crowns each) to compare different structural designs. Group 1 (Control) used a conventional full zirconia crown.

View Article and Find Full Text PDF

Purpose: To analyze the repair effect of glass fiber post combined with zirconia all ceramic crown in tooth defects and explore the relevant factors affecting the therapeutic effect.

Methods: A total of 100 patients(142 teeth) with dental defects admitted to Shandong Provincial Chronic Disease Hospital from January 2018 to January 2021 were selected as the study subjects. They were divided into an experimental group (glass fiber post combined with zirconia all ceramic crown restoration) with 70 patients(98 teeth) and the control group (metal post combined with zirconium dioxide all ceramic crown) with 30 patients (44 teeth).

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the biomechanical performance of different designs of three-unit implant-supported prostheses using two materials (Zirconia and PEKK) under various loading conditions.
  • Three models were created with different implant placements to analyze three designs: distal cantilever, fixed-fixed, and mesial cantilever, utilizing finite element analysis for stress evaluation.
  • Results indicated that the fixed-fixed design performed best, with PEKK showing lower stress in some areas but higher stress in others compared to Zirconia, highlighting the importance of design and material choice in prosthodontics.
View Article and Find Full Text PDF

3D-finite element analysis and weibull analysis of maxillary first molar restored with endocrowns with different pulpal extensions compared with conventional crowns with post-and-core.

Comput Biol Med

December 2024

Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China. Electronic address:

Background: Rehabilitation of endodontically treated teeth with large coronal destruction is still a clinical challenge. No established guidelines specify where a conventional crown with fiber-reinforced composite (FRC) post-and-resin core or an endocrown (EC) is indicated and which material or pulpal extension should be used.

Objective: To provide evidence for restoring severely damaged maxillary first molar (MFM) by comparing the fracture and debonding resistance after being restored with the ceramic EC and the conventional zirconia crown and FRC post-and-resin core.

View Article and Find Full Text PDF

Fracture resistance, 3-dimensional finite element analysis, and safety factors for five post-and-core restorations with crowns placed in the noncircular-shaped canals of premolars.

J Prosthet Dent

December 2024

Assistant Professor, Division of Prosthodontics, Faculty of Dentistry, Research Unit in Remineralized Tissue Reconstruction, Thammasat University, Pathumthani, Thailand. Electronic address:

Statement Of Problem: Restoring endodontically treated premolars with noncircular canals presents a significant challenge.

Purpose: The purpose of this study was to compare the in vitro fracture resistance and the finite element computational calculation-based stress and safety factor of noncircular-shaped, endodontically treated premolars restored with 5 different prefabricated and custom computer-aided design and computer-aided manufactured post-and-core systems.

Material And Methods: Fifty single-rooted oval-shaped canal maxillary premolars were endodontically treated and post spaces were prepared.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!