Long-term left ventricular support in patients with a mechanical aortic valve.

Scand Cardiovasc J

Division of Cardiovascular Medicine, Department of Medicine and Health Sciences, Faculty of Health Sciences, Linköping University, Department of Cardiovascular Surgery, County Council of Östergötland, Linköping, Sweden.

Published: August 2013

Objectives: The presence of a mechanical prosthesis has been regarded as an increased risk of thromboembolic complications and as a relative contraindication for a left ventricular assist device (LVAD). Five patients in our center had a mechanical aortic valve at the time of device implantation and were studied regarding thromboembolic complications.

Design: Five patients operated upon with an LVAD (1 HeartMate I™, 4 HeartMate II™) between 2002 and 2011 had a mechanical aortic valve at the time of implantation. The first patient had a patch closure of the aortic valve. In four patients, the prosthesis was left in place. Anticoagulants included aspirin, warfarin, and clopidogrel.

Results: The average and accumulated treatment times were 150 and 752 days, respectively. Three of the five patients showed early signs of valve thrombosis on echo with concomitant valve dysfunction. Four patients were transplanted without thromboembolic events during pump treatment. One patient died from a hemorrhagic stroke after 90 days on the LVAD.

Conclusions: The strategy of leaving a mechanical heart valve in place at the time of LVAD implantation in five patients led to valvular thrombosis in three but did not provoke embolic events. It increased the complexity of postoperative anticoagulation.

Download full-text PDF

Source
http://dx.doi.org/10.3109/14017431.2013.795655DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
mechanical aortic
12
left ventricular
8
valve time
8
patients
7
valve
7
mechanical
5
long-term left
4
ventricular support
4
support patients
4

Similar Publications

Since the first transcatheter aortic valve replacement (TAVR) was performed in China in 2010, TAVR has developed rapidly. However, the temporal trends in the 1-year prognosis after TAVR in China have not been described. This study enrolled patients treated at a high-volume Chinese TAVR center, West China Hospital, between 2015 and 2022, to analyze and characterize the temporal trends in 1-year outcomes.

View Article and Find Full Text PDF

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

The VACTERL (vertebral defects, anal atresia, cardiac defects, tracheoesophageal fistula, renal anomalies, and limb abnormalities) association represents an enigmatic syndrome requiring further study. This report describes a full-term neonate born to a multiparous woman who was found, upon further examination, to have multiple congenital abnormalities, including a bicuspid aortic valve, patent foramen ovale, tracheoesophageal fistula (TEF), asymmetric crying facies, microphallus, and a single inguinal testis. The discussion explores environmental and genetic factors that may contribute to this association, as well as similar conditions, such as CHARGE (coloboma, heart defects, choanal atresia, growth retardation, genital abnormalities, and ear abnormalities) syndrome.

View Article and Find Full Text PDF

The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!