Using a novel noninvasive, visible-light optical diffusion oximeter (T-Stat VLS Tissue Oximeter; Spectros Corporation, Portola Valley, CA) to measure the tissue oxygen saturation (StO2) of the buccal mucosa, the correlation between StOz and central venous oxygen saturation (ScvO2) was examined in children with congenital cyanotic heart disease undergoing a cardiac surgical procedure. Paired StO2 and serum ScvO2 measurements were obtained postoperatively and statistically analyzed for agreement and association. Thirteen children (nine male) participated in the study (age range, 4 days to 18 months). Surgeries included Glenn shunt procedures, Norwood procedures, unifocalization procedures with Blalock-Taussig shunt placement, a Kawashima/ Glenn shunt procedure, a Blalock-Taussig shunt placement, and a modified Norwood procedure. A total of 45 paired StO2-ScvO2 measurements was obtained. Linear regression demonstrated a Pearson's correlation of .58 (95% confidence interval [CI], .35-.75; p < .0001). The regression slope coefficient estimate was .95 (95% CI, .54-1.36) with an interclass correlation coefficient of .48 (95% CI, .22-.68). Below a clinically relevant average ScvO2 value, a receiver operator characteristic analysis yielded an area under the curve of .78. Statistical methods to control for repeatedly measuring the same subjects produced similar results. This study shows a moderate relationship and agreement between StO2 and ScvO2 measurements in pediatric patients with a history of congenital cyanotic heart disease undergoing a cardiac surgical procedure. This real-time monitoring device can act as a valuable adjunct to standard noninvasive monitoring in which serum SyvO2 sampling currently assists in the diagnosis of low cardiac output after pediatric cardiac surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4360981 | PMC |
Exp Physiol
January 2025
Integrative Cerebrovascular and Environmental Physiology SB Laboratory, University of Guelph, Guelph, Ontario, Canada.
Curr Opin Pediatr
December 2024
Division of Neonatology, Montreal Children's Hospital, McGill University Health Center, Montreal, Quebec, Canada.
Purpose Of Review: This review outlines the prevalence and complications of apneas and intermittent hypoxemic events in preterm infants, examines current monitoring limitations in neonatal ICUs (NICUs), and explores emerging technologies addressing these challenges.
Recent Findings: New evidence from the Prematurity-Related Ventilatory Control (Pre-Vent) study, which analyzed cardiorespiratory data from 717 extremely preterm infants, exposes the varying frequency, duration, and severity of apneas, intermittent hypoxemia, bradycardias, and periodic breathing during hospitalization, and highlights the negative impact of intermittent hypoxemia on pulmonary outcomes at discharge. Although traditional monitoring methods cannot differentiate between apnea types and quantify their burden, recent advancements in sensor technologies and data integration hold promise for improving real-time detection and evaluation of apneas in the NICU.
Objective: Evaluation of the effectiveness of vestibuloplasty according to microhemodynamics and oxygenation in the mucous membrane of the alveolar ridge.
Materials And Methods: To achieve this goal, a clinical and functional study was carried out in the mucous membrane of the alveolar ridge after vestibuloplasty in 80 patients (35 men and 45 women) aged from 18 to 65 years, average age 41.5±1.
Crit Care Explor
January 2025
Division of Cardiovascular Critical Care Medicine, Department of Cardiology, Boston Children's Hospital, Boston, MA.
Background: Accurate assessment of oxygen delivery relative to oxygen demand is crucial in the care of a critically ill patient. The central venous oxygen saturation (Svo) enables an estimate of cardiac output yet obtaining these clinical data requires invasive procedures and repeated blood sampling. Interpretation remains subjective and vulnerable to error.
View Article and Find Full Text PDFNatl J Maxillofac Surg
November 2024
C.B.M.R., Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
Background: Increased attention has been focused on the association of periodontal disease with cardio-metabolic syndrome. Although the associations are multi-factorial, very few studies have explored the role of lipoprotein Apo A1 and Apo B100 with chronic periodontitis. Additionally, obstructive sleep apnea (OSA), a chronic multi-factorial respiratory disease, consists of a temporary decrease or cessation of breath for ≥ 10 seconds and leads to a reduction in blood oxygen saturation of more than 3% to 4% and/or neurological arousal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!