Silicone oil used for endotamponade of retinal detachment may migrate into the subarachnoid space of the brain, including the cerebral ventricles, presumably by extension through silicone oil-filled spaces in the optic nerve. Silicone oil has characteristic appearances on CT scans and MRI, which can be utilized to distinguish it from more ominous entities. We describe a case of intraventricular silicone in a patient who presented with seizures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jocn.2012.09.037 | DOI Listing |
J Colloid Interface Sci
December 2024
Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China. Electronic address:
The depletion of lubricants in (slippery liquid-infused porous surfaces) SLIPS poses a significant challenge to their long-term functionality. While line-shaped rough structures can mitigate lubricant loss to some extent, they often fail to provide the stability required for sustained performance. In this study, we present a novel porous nanoflower aluminum alloy slippery liquid-infused surface (P-NF-AA SLIPS), which integrates a porous framework with a rough nanoflower structure.
View Article and Find Full Text PDFPLoS One
December 2024
Division of Ophthalmology, Department of Special Surgery, Faculty of Medicine, Jordan University of Science & Technology, Irbid, Jordan.
Purpose: The emulsification of silicone oil (SO) remains poorly understood. In the present study, we investigated the physical properties of unused pharmaceutical SO samples under various conditions. Moreover, clinical correlations with the patients' SO samples were assessed.
View Article and Find Full Text PDFRetin Cases Brief Rep
October 2024
Texas Retina Associates, Dallas, Texas.
Purpose: This report describes the use of the injectable intravitreal fluocinolone acetonide 0.18mg implant (FAI) for chronic postoperative cystoid macular edema (CME) in an eye with a silicone oil-filled vitreous cavity.
Methods: A retrospective chart review was performed including surgical, clinical, and imaging data.
Sci Rep
December 2024
Hubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan, 430100, China.
The application of classic foaming agent faces several issues, including excessive use of defoaming agent, inadequate defoaming, pipeline blockage due to silicone oil precipitation, and high development cost of the foaming agent. To address the aforementioned issues, a novel intelligent foaming agent was created. This resulted in the development of a new intelligent foaming and discharging agent system.
View Article and Find Full Text PDFArch Soc Esp Oftalmol (Engl Ed)
December 2024
Departamento de Oftalmología, Hospital Universitario Virgen de la Macarena, Sevilla, Spain; Miembros de la «Red de Enfermedades Inflamatorias, Enfermedades Inflamatorias Oculares, Enfermedades Inflamatorias No Infecciosas de la Superficie Ocular, Instituto de Salud Carlos III (RICORS). FISS-21-RD21/0002/0011»; Área de Oftalmología, Departamento de Cirugía, Universidad de Sevilla, Sevilla, Spain.
Although silicone oil is used as an intraocular buffer in vitreoretinal surgical procedures, its use can cause complications, including glaucoma. This study highlights the importance of individualized approaches for the management of silicone oil-induced glaucoma. A 62-year-old man with a past medical history of retinal detachment and multiple ocular surgical procedurespresented with uncontrolled ocular pressure peaks after retinal detachment surgery using silicone oil as a buffer, which did not resolve after removal of the buffer.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!