A modified technique for placement of the venous outflow component (VOC) of the Hemodialysis Reliable Outflow (HeRO) device (Hemosphere Inc, Minneapolis, Minn) is described. The purpose of the technique is to improve the system's trackability and facilitate device insertion in patients with central venous occlusion. Device preparation requires placement of a 6-mm × 4-cm angioplasty balloon within the leading end of the VOC. The leading 2 cm of the balloon are placed just distal to the radiopaque marker of the VOC. The balloon is inflated to profile and locked in this position within the leading end of the VOC. The VOC and balloon combination is advanced over the wire through the 20F peel-away sheath provided by the manufacturer. The described technique was used to successfully implant the HeRO device in 12 patients with central venous occlusion. This technique is recommended for placement of the VOC of the HeRO device in patients with central venous occlusions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2013.03.011 | DOI Listing |
Semin Vasc Surg
December 2024
Department of Surgery, Division of Vascular and Endovascular Surgery, Duke University Medical Center, Durham, NC. Electronic address:
Hemodialysis (HD) access failure is a frequent problem encountered by vascular surgeons. As treatment of end-stage renal disease improves and patients live longer on HD, eventual exhaustion of traditional upper extremity HD access is common. Efforts to preserve and maintain these accesses are essential.
View Article and Find Full Text PDFJ Clin Aesthet Dermatol
January 2024
Ms. Hennessey is the Owner of Blush Aesthetics in Perrysburg and Toledo, Ohio, and Assistant Professor, Nursing, Gonzaga University in Spokane, Washington.
J Conserv Dent Endod
July 2024
Department of Conservative Dentistry and Endodontics, Malla Reddy Dental College Foe women, Telangana, India.
Context: Endodontic success hinges on a multifactorial interplay, with meticulous canal shaping, proper disinfection, and three-dimensional obturation being paramount. Among these factors, the amount of dentin remaining after instrumentation directly influences the biomechanical resilience and longevity of the tooth.
Aims: This study aims to evaluate the impact of various rotary instrumentation systems, including single-file, two-file, and multiple-file configurations, on the remaining dentin thickness (RDT) following canal preparation.
J Assoc Physicians India
August 2024
Secretary, General Physician, Association of Physicians of India (API), Ajmer, Rajasthan, India.
In India and the Southeast Asian population, hypertension and type 2 diabetes mellitus (T2DM) are the leading lifestyle-related diseases, responsible for a majority burden of morbidity and mortality. Multiple population-spanning studies have revealed the staggering prevalence of both diseases in India, and the prevalence of both will only increase further due to factors such as an aging population, rapid urbanization, increased obesity, and sedentary lifestyles. More than 50 percent of hypertensive patients in India are also diagnosed with T2DM, and a detailed management protocol for the same is required, especially when a major portion of the disease is managed at the primary care level.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!