Orthopaedics is currently the largest market of biomaterials worldwide and implant-related infections, although relatively rare, remain among the first reasons for joint arthroplasty and osteosynthesis failure. Bacteria start implant infection by adhering to biomaterials and producing biofilms, which represent a major reason for bacterial persistence, in spite of antibiotic treatment and host's defence. In the last two decades, a number of different antibiofilm agents have been studied and both in vitro and in vivo results appear now promising, even if their effective role in orthopaedics remains to be assessed. In this review, we introduce an original classification of antibiofilm agents, based on their mechanism of action and examine the available data concerning their possible application to orthopaedic implant-related infections. Molecules that interfere with biofilm production (biofilm prevention agents) include anti-adhesion compounds, quorum sensing inhibitors, non-steroideal anti-inflammatory drugs, and antimicrobial peptides; N-acetylcysteine and specific enzymes promise the greatest therapeutic possibilities by disrupting established biofilms (biofilm disrupting agents). The identification of antimicrobials able to bypass the biofilm barrier (biofilm bypassing agents), and antibiofilm vaccines are further strategies aimed to reduce the impact of biofilm-related infections, opening new pathways in controlling implant-related infections. However, this review shows that still insufficient knowledge is currently available as to regard the efficacy and safety of the investigated antibiofilm strategies to treat infection that involve bone tissue and biomaterials commonly implanted in orthopaedics, pointing out the need for further research in this promising field.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1179/1973947812Y.0000000045 | DOI Listing |
ACS Omega
January 2025
School of Stomatology, Lanzhou University, Lanzhou 730000, China.
Bone defects that exceed the critical defect value, resulting from fractures and diseases, are often difficult to heal. Although bone tissue engineering is a promising treatment for extensive osseous defects, orthopedic-implant-related infections increase the likelihood of failure. Bioactive glass (BG) has been widely used in the manufacture of artificial bone scaffolds, owing to its excellent biocompatibility and osteoinductivity.
View Article and Find Full Text PDFCureus
December 2024
Orthopedics, Queensland Health, Toowoomba, AUS.
Open ankle fractures in the elderly are increasingly common, with significant morbidity and mortality. Management is challenging due to poor soft tissue conditions, comorbidities, and limited functional independence. While traditional surgical options include external fixation or open reduction and internal fixation (ORIF), hindfoot nail (HFN) fixation may offer advantages, including immediate weight-bearing and reduced immobilisation complications.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Adult Reconstruction and Joint Replacement Service, Division of Sports Traumatology and Joint Surgery, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, Roma, RM 00168, Italy.
Introduction: Total hip arthroplasty (THA) surgeries are rapidly increasing due to an aging population, leading to an increase in degenerative hip osteoarthritis. However, 1% of these patients go through prosthetic joint infection (PJI), which gives rise to implant failure with prolonged periods of patient incapacitation and higher mortality risk.
Case Report: In this article, we report an unusual case of a 62-year-old male who developed a PJI 7 months after a THA.
ACS Appl Mater Interfaces
January 2025
Process Engineering Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamilnadu 630003, India.
The present study aims to analyze the thermal regulation of the Ce/Ce ratio on the nanonetwork titania layer over the titanium (Ti) surface developed by the alkali-mediated surface modification approach. The effect of sequential heat treatment from 200 to 800 °C was evaluated for its surface characteristics such as morphology, phase formation, roughness, hardness, hydrophilicity, etc. Surface oxidation by temperatures up to 600 °C demonstrated a progressive increase in the Ce (CeO) content with a rutile TiO network layer over the Ti surface.
View Article and Find Full Text PDFColloids Surf B Biointerfaces
December 2024
College of Chemical Engineering, Xinjiang Normal University, 102 Xinyi Road, Urumqi 830054, P.R. China. Electronic address:
Infection and insufficient osseointegration are the primary factors leading to the failure of titanium-based implants. Surface coating modifications that combine both antibacterial and osteogenic properties are commonly employed strategies. However, the challenge of achieving rapid antibacterial action and consistent osteogenesis with these coatings remains unresolved.