The authenticity, the grape variety, the geographical origin, and the year of vintage of wines produced in Germany were investigated by (1)H NMR spectroscopy in combination with several steps of multivariate data analysis including principal component analysis (PCA), linear discrimination analysis (LDA), and multivariate analysis of variance (MANOVA) together with cross-validation (CV) embedded in a Monte Carlo resampling approach (MC) and others. A total of about 600 wines were selected and carefully collected from five wine-growing areas in the southern and southwestern parts of Germany. Simultaneous saturation of the resonances of water and ethanol by application of a low-power eight-frequency band irradiation using shaped pulses allowed for high receiver gain settings and hence optimized signal-to-noise ratios. Correct prediction of classification of the grape varieties of Pinot noir, Lemberger, Pinot blanc/Pinot gris, Müller-Thurgau, Riesling, and Gewürztraminer of 95% in the wine panel was achieved. The classification of the vintage of all analyzed wines resulted in correct predictions of 97 and 96%, respectively, for vintage 2008 (n = 318) and 2009 (n = 265). The geographic origin of all wines from the largest German wine-producing regions, Rheinpfalz, Rheinhessen, Mosel, Baden, and Württemberg, could be predicted 89% correctly on average. Each NMR spectrum could be regarded as the individual "fingerprint" of a wine sample, which includes information about variety, origin, vintage, physiological state, technological treatment, and others.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jf400800d | DOI Listing |
Anal Chim Acta
January 2025
Department of Chemistry, Indian Institute of Technology Ropar, Rupnagar, Punjab, 140001, India. Electronic address:
Background: The unregulated use of pesticides by farmers, for crop productivity results in widespread contamination of organophosphates in real environmental samples, which is a growing societal concern about their potential health effects. The conventional approaches for the monitoring these organophosphate-based pesticides which include immunoassays, electrochemical methods, immunosensors, various chromatography techniques, along with some spectroscopic methods, are either costly, sophisticated, or involves the use of different metal complexes. Therefore, there is an urgent need for sensitive, quick, and easy-to-use detection techniques for the screening of widely used organophosphate-based pesticides.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Department of Food Engineering and Technology, Tezpur University, Napaam, Sonitpur, Tezpur, Assam, India. Electronic address:
Microwave-assisted extraction of pectin from Dillenia indica (DI) fruit was optimized using Box-Behnken design to maximize yield and quality. Parameters such as solid:solvent (1:10-1:30), microwave power (200-600 W), and extraction time (4-10 min) were varied to determine the optimal conditions. Through experimentation, the optimized extraction parameters were identified as 1:23.
View Article and Find Full Text PDFCir Cir
January 2025
Department of Neurosurgery, Spinal Health Center, Memorial Hospital, Istanbul, Turkey.
Objective: We aimed to elucidate the histopathological pre-diagnosis of cranial gliomas with magnetic resonance imaging (MRI) techniques in gliomas.
Method: A total of 82 glioma patients were enrolled to our study. Pre-operative conventional MRI images (non-contrast T1/T2/flair/contrast-enhanced T1) and advanced MRI images (DAG and ADC mapping, MRI spectroscopy and perfusion MRI [PMRI]) were analyzed.
J Crohns Colitis
January 2025
Professor of Gastroenterology, Translational Medical Sciences, School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham; NIHR Nottingham Biomedical Research Centre, Nottingham.
Background & Objective: IBD fatigue aetiology is poorly understood. This study quantified body composition and physical function alongside proton magnetic resonance imaging (1H MRI) and spectroscopy (31P MRS) measures of organ structure and function in quiescent Crohn's Disease patients (CD) and healthy volunteers (HV), to identify a physiological basis for IBD fatigue.
Methods: Body composition was determined using DEXA and 1H MRI.
ACS Nano
January 2025
Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Ordered nanoporous polymer membranes offer opportunities for systematically probing the mechanisms of ion transport under confinement and for realizing useful materials for electrochemical devices. Here, we examine the impact of morphology and ion hydration on the transport of hydroxide and bromide anions in nanostructured polymer membranes with 1 nm scale pores. We use aqueous lyotropic self-assembly of an amphiphilic monomer, with a polymerizable surfactant to create direct hexagonal (H) and gyroid mesophases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!