Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used.
Materials And Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system.
Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient.
Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3654464 | PMC |
http://dx.doi.org/10.4103/0019-5413.108899 | DOI Listing |
A coherent optical frequency comb (OFC) with suppressed linewidth is demonstrated based on the spectral broadening of a directly modulated semiconductor microcavity laser with self-injection locking. Due to the high electro-optical response, the directly modulated microcavity laser provides a 10-GHz-spaced seeding OFC with 9 comb teeth in a 10 dB flatness window. Besides, an optical feedback fiber loop with two sub-loops is introduced to reduce the linewidth of the microlaser and suppress the undesired longitudinal modes.
View Article and Find Full Text PDFWe demonstrated what is believed to be the first 1.2 GHz nonlinear polarization rotation stretched-pulse mode-locked Yb:fiber laser with a compact design and innovative components. With a compact Faraday rotation angle has been used in NPR mode-locked lasers, and we find that incomplete isolation of backward-propagating light does not hinder self-starting.
View Article and Find Full Text PDFSci Rep
January 2025
Departmant of Orthopedics and Traumatology, Liv Ulus Hospital, Istanbul, Turkey.
Locking plates have a rapidly growing process especially in the past decades and results are satisfactory especially in the osteoporotic bones compared to non-locking compression plates. There are many forms of failure in the fracture fixation of locking plates, and screw pull-out is one of the main failure reasons. In this study, we aim to investigate pull-out failure in locking plates using locking spongious screws.
View Article and Find Full Text PDFVet Comp Orthop Traumatol
January 2025
School of Engineering, University of Guelph, Guelph, Ontario, Canada.
Objective: To determine the effect of locking head inserts (LHI) on plate strain, stiffness, and deformation when applied to a 3.5-mm broad locking compression plate (LCP) in an open fracture-gap model.
Study Design: Six, 13-hole, 3.
J Vet Dent
January 2025
Department of Dentistry, Oral and Maxillo-facial Surgery, Eastcott Veterinary Referrals, Part of Linnaeus Group, Swindon, UK.
Canine acanthomatous ameloblastoma (CAA) is an invasive benign epithelial odontogenic tumour most commonly affecting the mandible of large breed dogs. To the author's knowledge, this report describes the first computer-aided design patient-specific implant (PSI) that has been placed for a critical sized bone defect in mandibular reconstruction of a dog in the UK. The aim was to restore mandibular stability using a regenerative approach combining a titanium locking plate and compression-resistant matrix infused with recombinant human bone morphogenetic protein-2 (rhBMP-2) to bridge the 85 mm mandibular defect created by a segmental mandibulectomy.