A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sensitive indirect spectrophotometric method for determination of h2-receptor antagonists in pharmaceutical formulations. | LitMetric

Sensitive indirect spectrophotometric method for determination of h2-receptor antagonists in pharmaceutical formulations.

Int J Biomed Sci

Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt;

Published: June 2007

A simple, accurate and sensitive spectrophotometric method has been developed and validated for determination of H2-receptor antagonists: cimetidine, famotidine, nizatidine, and ranitidine hydrochloride. The method was based on the oxidation of these drugs with cerium (IV) in presence of perchloric acid and subsequent measurement of the excess Ce (IV) by its reaction with p-dimethylaminocinnamaldehyde to give a red colored product (λmax at 464 nm). The decrease in the absorption intensity (ΔA) of the colored product, due to the presence of the drug was correlated with its concentration in the sample solution. Different variables affecting the reaction were carefully studied and optimized. Under the optimum conditions, linear relationships with good correlation coefficients (0.9985-0.9994) were found between ΔA values and the concentrations of the drugs in a concentration range of 1-16 µg ml(-1). The assay limits of detection and quantitation were 0.12-0.44 and 0.37-1.33 µg ml(-1), respectively. The method was validated, in terms of accuracy, precision, ruggedness, and robustness; the results were satisfactory. The proposed method was successfully applied to the analysis of the investigated drugs in their pure and pharmaceutical dosage forms (recovery was 98.8-102.5 ± 0.79-1.72%) without interference from the common excipients. The results obtained by the proposed method were comparable with those obtained by the official methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614635PMC

Publication Analysis

Top Keywords

spectrophotometric method
8
determination h2-receptor
8
h2-receptor antagonists
8
colored product
8
µg ml-1
8
proposed method
8
method
6
sensitive indirect
4
indirect spectrophotometric
4
method determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!