Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
An innovative approach for measuring phytase activity (PA) in surface water is presented. A substrate analog of -inositol hexakis(dihydrogen) phosphate (InsP), commonly referred to as phytic acid, 1--5--(1-oxo-1-(2' ,4,7,7' -tetrachloro-3',6'-dihydroxy-3-oxo-3H-spiro[isobenzofuran-1,9'-xanthen]-6-yl)-5,8,11-trioxa-2-azatridecan-13-yl)-inositol 1,2,3,4,6-pentakis--(dihydrogen) phosphate, referred to as tetrachlorofluorescein (TET) tethered (T)InsP, has been developed that can be used to monitor the (phytase-catalyzed) phosphate ester bond-cleavage reaction. Test phytases, (wheat [4-] and [3-] phytase) sequentially remove phosphate groups from TET TInsP, producing dephosphorylated probe species that were readily separated by reversed-phase high-performance liquid chromatography (RP-HPLC). Because dephosphorylated probe species retain the TET group, highly sensitive quantification could be achieved using fluorescence detection (excitation/emission ' = 245/540 nm). Calibration curves for TET TInsP, which could be used as a standard for quantifying all probe species, were linear ( > 0.999) over the range of concentrations tested. Phytase-generated dephosphorylated probe species were characterized or identified using RP-HPLC with mass spectrometry. Results of mass spectrometry analysis show that the RP-HPLC system was capable of distinguishing between dephosphorylated probe species at the regioisomeric level. The TET TInsP molecular probe was used to successfully measure PA in pond water. We found that the PA associated with the particulate plus water-soluble fraction was greater than that observed for the water-soluble fraction alone. Moreover, it appeared that 4- and 3-phytase were active in pond water based on an analysis of the chromatographic profile (i.e., elution sequence) of dephosphorylated probe species produced. The advent of a fluorescent substrate analog of InsP affords environmental scientists with the means to unambiguously quantify an extremely small amount of phytase-generated dephosphorylated product(s), enabling the measurement of PA over a reasonably short time duration, in an environmental sample containing low concentrations of enzyme.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2134/jeq2012.0204 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!