The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10439-013-0822-6 | DOI Listing |
J Electromyogr Kinesiol
January 2025
Research Academy of Grand Health, Faculty of Sports Sciences, Ningbo University, Ningbo, China. Electronic address:
Objective: We investigated the characteristics of hip, knee, and ankle joint reaction forces (JRFs) in stroke patients with spastic hemiplegia during sit-to-stand (Si-St) and stand-to-sit (St-Si) movements and explored the relationship between JRFs and joint moments.
Methods: Thirteen stroke patients with spastic hemiplegia and thirteen age-matched healthy subjects were recruited in this study. Three-dimensional motion capture system and force plates were employed to collect kinematic data and ground reaction forces during Si-St and St-Si tasks.
BMC Musculoskelet Disord
January 2025
Department of Orthopedics and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China.
Background: Osteonecrosis of the femoral head (ONFH) is a challenging condition, primarily affecting young and middle-aged individuals, which results in hip dysfunction and, ultimately, femoral head collapse. However, the comparative effectiveness of joint-preserving procedures, particularly in the early stages of ONFH (ARCO stage I or II), remains inconclusive. This study aims to evaluate the efficacy of a novel technique called small-diameter core decompression (CD) combined with platelet-rich plasma (PRP), for the treatment of early-stage ONFH.
View Article and Find Full Text PDFJ Knee Surg
January 2025
Lenox Hill Hospital Department of Orthopedic Surgery, Northwell Health, New York, United States.
Patellar instability following total knee arthroplasty (TKA) is a rare, yet serious complication, potentially requiring revision surgery or resulting in chronic dysfunction. When encountered, it is paramount to understand the etiologies, diagnostic approaches, treatment options, and outcomes of the selected treatment. The most common cause of patella instability is improper positioning of components, leading to lateral maltracking of the patella.
View Article and Find Full Text PDFJ Appl Biomech
January 2025
Rehabilitation Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Knee osteoarthritis (KOA) can have more pronounced effects on joint position sense (JPS) accuracy and gait characteristics. The aim of this study is to investigate the association between lower limb JPS and different aspects of gait pattern including gait asymmetry and variability and spatiotemporal coordination in individuals with bilateral KOA. In this cross-sectional study, lower limb JPS of 43 individuals with bilateral KOA (mild and moderate) were measured.
View Article and Find Full Text PDFJ Appl Biomech
January 2025
Lancaster Medical School, Faculty of Health and Medicine, Lancaster University, Lancaster, United Kingdom.
This study compares joint kinematics and kinetics of young stroke survivors who walk <0.79 m/s (slow) or >0.80 m/s (fast) with reference to a healthy able-bodied group and provides clinical recommendations for guiding the gait rehabilitation of stroke survivors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!