Automatic classification of the interferential tear film lipid layer using colour texture analysis.

Comput Methods Programs Biomed

Departamento de Computación, Universidade da Coruña, Campus de Elviña S/N, 15071 A Coruña, Spain.

Published: July 2013

The tear film lipid layer is heterogeneous among the population. Its classification depends on its thickness and can be done using the interference pattern categories proposed by Guillon. This papers presents an exhaustive study about the characterisation of the interference phenomena as a texture pattern, using different feature extraction methods in different colour spaces. These methods are first analysed individually and then combined to achieve the best results possible. The principal component analysis (PCA) technique has also been tested to reduce the dimensionality of the feature vectors. The proposed methodologies have been tested on a dataset composed of 105 images from healthy subjects, with a classification rate of over 95% in some cases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2013.04.007DOI Listing

Publication Analysis

Top Keywords

tear film
8
film lipid
8
lipid layer
8
automatic classification
4
classification interferential
4
interferential tear
4
layer colour
4
colour texture
4
texture analysis
4
analysis tear
4

Similar Publications

Purpose: We aimed to evaluate the effects of autologous serum plus artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery.

Methods: A total of 150 patients with mild to moderate xerophthalmia after one-time cataract surgery from March 2022 to September 2023 were selected and randomly divided into a control group (n = 75) and a study group (n = 75). The control group was treated with artificial tears (polyvinyl alcohol eye drops), while the study group was given autologous serum plus artificial tears.

View Article and Find Full Text PDF

Terahertz (THz) waves reside in the electromagnetic spectrum between the microwave and infrared bands. In recent decades, THz technology has demonstrated its potential for biomedical applications. With the highly unique characteristics of THz waves, such as the high sensitivity to water and optimal spatial resolution coupled with the characteristics of the human cornea, such as its high water content, THz technology has been explored as a potential modality to assess corneas and corneal diseases.

View Article and Find Full Text PDF

Lifitegrast in Treatment of Dry Eye Disease-A Practical, Narrative Expert Review.

J Ophthalmol

January 2025

Department of Ophthalmology, Oslo University Hospital, P.O. Box 4950, Nydalen, Oslo 0424, Norway.

Dry eye disease (DED) is a multifactorial disorder affecting millions worldwide. Inflammation plays a central role in DED. The aim of this review is to critically evaluate the literature concerning the efficacy and safety of lifitegrast, a small molecule immunomodulator that blocks the action of lymphocyte function-associated antigen-1.

View Article and Find Full Text PDF

Background: Diabetes-associated dry eye syndrome (DMDES) affects 20-54 % of diabetes, leading to ocular irritation and blurry vision. Decreased conjunctival goblet cell mucus secretion is one of the major pathological processes of DMDES. This study aims to investigate the mechanism of mucus granule maturation and secretion disturbance in DMDES.

View Article and Find Full Text PDF

Investigating the Relative Importance of Tear Homeostatic Signs for the Diagnosis of Dry Eye Disease.

Ocul Surf

January 2025

Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; College of Health & Life Sciences, School of Optometry, Aston University, Birmingham, UK.

Aim: Disease misdiagnosis is more likely if standardised diagnostic criteria are not used. This study systematically examined the effect on diagnosing dry eye disease (DED), when tests for evaluating tear film homeostasis were included/excluded from a multi-test protocol.

Method: For 1427 participants across five sites, data for the full suite of diagnostic tests defined in the Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS II) Diagnostic Methodology report algorithm were evaluated; diagnostic sensitivity was calculated when individual signs were removed, and when different combinations of signs were required.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!